background image

  
   

Configuration and Options Guide

                                             

EMEA

 

                                       

 

xSeries

Netfinity

Rack products

Fibre Channel

Storage Enclosures

Clustering

Cables

Options

        

 February 28th 2001

Summary of Contents for eServer xSeries

Page 1: ...Configuration and Options Guide EMEA xSeries Netfinity Rack products Fibre Channel Storage Enclosures Clustering Cables Options February 28th 2001...

Page 2: ...es 220 xSeries 230 Netfinity 5100 IBM FAStT EXP500 Storage Enclosure IBM Rack Enclosure xSeries 130 xSeries 135 xSeries 150 xSeries 330 xSeries 340 Netfinity 4500R Netfinity 7600 Netfinity7100 IBM FAS...

Page 3: ...at URL http www pc ibm com europe configurators Yes No 6 Other Comments 7 Are you a Check one PC Dealer IBM Employee IBM Customer PC Distributor IBM Sales Rep Large Account Customer PC VAR Other _____...

Page 4: ...9K4401 x230 NF 7100 I O CHARTS ADDED TOKEN RING ADAPTER P N 34L5201 x230 I O CHART CLARIFICATION OF WHEN ADDITIONAL POWER SUPPLY IS NEEDED IN x230 x230 POWER MONITORS ACCESSORIES SECTION NOTE 1 AND TA...

Page 5: ...Series 340 and Netfinity 4500R 50 IBM Netfinity 6000R Configurator 58 IBM Netfinity 7100 Configurator 66 IBM Netfinity 7600 Configurator 74 IBM Netfinity 8500R Configurator 82 IBM EXP300 Configurator...

Page 6: ...to help evaluate the three year total cost of ownership estimation for different tape formats based on the following factors drive performance media usage cartridge changing costs cleaning frequency c...

Page 7: ...orld Wide Web use address http www ibm com pc SERVER PRODUCT POSITIONING Server Product Positioning File and Print Increasing Performance Capacity Availability Number of Clients x240 5600 x230 5100 x3...

Page 8: ...NetServer LXr 8000 4 way IBM Netfinity 7100 Compaq ProLiant ML570 Dell PowerEdge 6400 HP NetServer LH4 IBM Netfinity 7600 Compaq No Offering Dell No Offering HP NetServer LXr 8000 IBM Netfinity 6000R...

Page 9: ...lication is stored locally For server stored applications cut number of users in half of Users 1200 1000 2100 2100 of Processors 1 2 2 2 Memory 2GB 768MB 2GB 2GB Hard Disk Drives 5 to 10 4 to 8 20 to...

Page 10: ...e Note 2 Users 162 180 312 245 245 375 Processors 2 2 4 4 4 8 Memory 1 to 2GB 1 to 2GB 2GB 2GB 2GB 4GB Hard Disk Drives 12 to 24 12 to 24 24 to 36 24 to 36 24 to 36 24 to 36 RAID Adapters 1 1 2 2 2 2...

Page 11: ...256MBR 4GB7 10 Tower 1 3 10 100OB 37L6091 3 x 37L7205 10 5 5 4 K861Yxx xSeries 240 K481Gxx 1GHz5 1 2 256 512MBR 4GB7 8 Tower 2 3 10 100OB 37L6091 3 x 37L7205 10 5 5 4 K481Yxx xSeries 330 15 04 01 K432...

Page 12: ...ready to use out of the box Pre loaded software includes Turbo Linux OS IBM HTTP Server Appliance System Management Advanced appliance configuration utility The xSeries 135 Appliance Server pre loaded...

Page 13: ...ade1 21P9539 800 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor All K81xXxx 10K3818 866 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium I...

Page 14: ...ess otherwise noted 2 The xSeries 200 EIDE controllers support a maximum of four IDE devices per machine including CD ROM drive hard disks and IDE tape drive 3 Not a supported configuration on model P...

Page 15: ...ncluded with optional Media Bay Tray and LVD Cable Kit P N 10K2340 External SCSI support can be obtained by installing an optional SCSI adapter or RAID controller and using appropriate external SCSI c...

Page 16: ...ith slots three and five 4 ServeRAID 4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel 16 MB of ECC cache and either one internal or one external U...

Page 17: ...ic country code DK Denmark IS Israel IT Italy SD Saudi Arabia SA South Africa CH Switzerland UK UK EU Europe 9 Where xxx represents the appropriate country code as follows DEN Denmark ISR Israel ITA I...

Page 18: ...s to which it is attached to Ultra SCSI speeds To provide a dedicated tape SCSI bus install PCI Wide Ultra160 SCSI Adapter P N 19K4646 which includes a five drop multi mode LVD SCSI cable 4 For RAID c...

Page 19: ...a with additional external storage expansion still available Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection This configuration also includes a tape backu...

Page 20: ...19 Updated 28 02 01...

Page 21: ...SMP Support1 Processor Speed Upgrade2 21P9539 800 MHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor All K52xXxx 10K3818 Netfinity 866 MHz with 133 MHz FSB and 256...

Page 22: ...200 SL 4 1 4 7 4 00N8205 18 2GB 7200 rpm Ultra160 SCSI HDD 7200 SL 4 1 4 7 4 00N8206 36 4GB 7200 rpm Ultra160 SCSI HDD 7200 SL 4 1 4 7 4 00N8207 9 1GB 10 000 rpm Ultra160 SCSI HDD 10 000 SL 4 1 4 7 4...

Page 23: ...upport a SCSI device in the 3 5 inch non hot swap bay while the second drop is connected to the hot swap SCSI backplane The SCSI backplane provides termination for the SCSI bus Other Configuration Alt...

Page 24: ...l channel and includes a five drop multi mode terminated LVD SCSI cable 3 ServeRAID 4L Ultra160 SCSI Controller is powered by a 100 MHz Intel i960 processor and provides a single channel 16 MB of ECC...

Page 25: ...y code DK Denmark IS Israel IT Italy SD Saudi Arabia SA South Africa CH Switzerland UK UK EU Europe 9 Where xxx represents the appropriate country code as follows DEN Denmark ISR Israel ITA Italy SDI...

Page 26: ...s To provide a dedicated tape SCSI bus install PCI Wide ultra160 SCSI Adapter P N 19K4646 which includes a five drop multi mode LVD SCSI cable 3 For RAID configurations where the standard SCSI cable i...

Page 27: ...ailable Demanding network traffic is effectively handled by the standard 100 Mbps Ethernet connection This configuration also includes a tape backup unit monitor and a UPS to keep the system protected...

Page 28: ...27 Updated 28 02 01...

Page 29: ...t P N 37L6881 are required for power supply redundancy See Power Monitors Accessories section for additional information 4 Variable read rate Actual playback speed will vary and is often less than the...

Page 30: ...RPM Ultra160 SCSI HDDs 9 1 GB P N 37L7201 18 2 GB P N 37L7202 36 4 GB P N 37L7203 9 1 GB P N 37L7204 18 2 GB P N 37L7205 36 4 GB P N 37L7206 9 1 GB P N 19K0655 18 2 GB P N 19K0656 0 GB 0GB Standard o...

Page 31: ...LVD Cable Kit P N 10K2340 and Hot Swap Power Supply Upgrade Kit P N 37L6881 3 Media Bay Tray and LVD Cable Kit P N 10K2340 is required It contains a two drop terminated LVD SCSI cable and the hardwar...

Page 32: ...nectors may be utilised 6 See Fibre Array Solutions section for additional configuration information 7 xSeries 230 Netfinity 5100 includes a full duplex 10 100 Mbps Ethernet PCI controller 8 The Wake...

Page 33: ...ity 5100 uses an SVGA controller S3 Savage4 chipset with 8 MB of video memory 8 Installation within a rack requires optional Monitor Compartment P N 94G7444 9 Installation within a rack requires optio...

Page 34: ...Units Controllers to select a cable for attaching the enclosure to the adapter 3 LVD support for LVD devices installed in a NetMEDIA Storage Expansion Unit EL P N 03K8756 requires replacement of the s...

Page 35: ...server differs from a file and print server in that it has a higher workload in providing application serving requirements for users With this in mind the xSeries 230 was selected to provide an afford...

Page 36: ...35 Updated 28 02 01...

Page 37: ...ntium III processor with advanced transfer full speed L2 cache and 133 Mhz Front Side Bus 3 High speed 133 MHz SDRAM 4 Robust configurations may require optional 250W Hot Swap Redundant Power Supply P...

Page 38: ...e Configurator TotalInt Storage1 7200 RPM Ultra160 SCSI HDDs 10 000 RPM Ultra160 SCSI HDDs 15 000 RPM Ultra160 SCSI HDDs 9 1 GB P N 37L7201 2 18 2 GB P N 37L7202 2 36 4 GB P N 37L7203 2 9 1 GB P N 37L...

Page 39: ...ot swap 7200rpm HDD bays 3 Not supported by the onboard external SCSI port To configure an external SCSI device select an optional SCSI controller then refer to see Appendix D Cables Storage Units Con...

Page 40: ...I connector Only one of the two connectors may be utilised 7 See Fibre Array Solutions section for additional configuration information 8 xSeries 240 Netfinity 5600 has an integrated 10 100 PCI Ethern...

Page 41: ...uires optional Netfinity Flat Panel Monitor Rack Mount Kit II P N 37L6888 and Netfinity Rack Keyboard Tray P N 28L4707 A space saver keyboard may coexist within the same keyboard tray 8 Rack Power Cab...

Page 42: ...rop multi mode terminated LVD SCSI cable included with Media Bay Tray and LVD Cable Kit P N 10K2340 for support of LVD devices in LVD mode Use of the included single ended terminated cable with an LVD...

Page 43: ...is designed for high availability This configuration includes 56 GB of internal HDD storage features a third power supply which provides fully redundant power a UPS to help protect the system against...

Page 44: ...43 Updated 28 02 01...

Page 45: ...K431Yxx 10K0053 1 GHz Upgrade with 133 MHz FSB and 256 KB Advanced Transfer Cache Pentium III Processor K451Yxx K411Yxx K431Yxx K441Yxx 1 One additional processor may be installed providing a maximum...

Page 46: ...controller supports the desired External Storage Expansion Unit and to select a supported cable For HDD or other expansion unit options see the specific expansion unit section 2 The EXP300 includes a...

Page 47: ...2 Systems Management12 36L96xx13 Netfinity Advanced System Management PCI Adapter Full 32 bit 1 03K9309 Netfinity Advanced System Management Interconnect Cable Kit 36L9654 Netfinity Advanced System M...

Page 48: ...Keyboard and Mouse7 06P4792 Cable Chain Technology Cable Kit7 8 28L36xx12 Space Saver II Keyboard9 28L36xx13 Preferred Keyboard stealth black 10 28L3675 Sleek 2 button Stealth Black Mouse 1 xSeries 33...

Page 49: ...riate cable must be selected All tape drives and enclosures are supported by PCI Wide Ultra160 SCSI Adapter P N 19K4646 which has an external 0 8 mm VHDCI connector Select tape drive enclosure and sup...

Page 50: ...selected to provide an affordable price point for an application server with two way Pentium III processing 512MB of system memory expandable to 4GB and availability features such as RAID protected i...

Page 51: ...umes installation of optional Netfinity 3 Pack Ultra160 Hot Swap Expansion Kit P N 33L5050 which converts the two available removable media bays into three slim line SL hot swap bays 6 Variable read r...

Page 52: ...s removal of standard memory xSeries 340 Netfinity 4500R Internal Hard Disk Drive HDD and External Storage Coinfigurator TotalInt Storage1 7200 RPM Ultra160 SCSI HDDs 10 000 RPM Ultra160 SCSI HDDs 15...

Page 53: ...ge Server5 6 8 Rack 3U 19K11xx11 FAStT 200 HA Storage Server5 8 Rack 3U 19K1121 FAStT 200 Redundant RAID Controller6 00N71xx12 FAStT EXP500 Storage Expansion Unit7 8 Rack 3U 94G7448 Rack Power Cable T...

Page 54: ...wo connectors may be utilised 6 PCI Fast Wide Ultra SCSI Adapter provides one external 68 pin high density connector The internal connectors are not accessible due to a cabling interference 7 See Fibr...

Page 55: ...UPS or PDU 9 Where xx represents a specific country code DK Denmark IS Israel IT Italy SD Saudi Arabia SA South Africa CH Switzerland UK UK EU Europe 10 Where xxx represents the appropriate country c...

Page 56: ...xpansion Unit EL P N 03K8756 requires replacement of the standard single ended internal cables with one or more depending on configuration cables from Media Bay Tray and LVD Cable Kit P N 10K2340 whic...

Page 57: ...r an application server with two way Pentium III processing 384 MB of system memory expandable to 4GB and availability features such as battery backed cache RAID protected internal hot swap storage an...

Page 58: ...57 Updated 28 02 01...

Page 59: ...edundant Power Supply P N 37L6879 Robust configurations may require two See Power under Netfinity 6000R Power Monitors Accessories for additional information 5 Variable read rate Actual playback speed...

Page 60: ...RDIMMs of the same size Install RDIMM sets in numerical sequence from 1 to 4 Chipkill support is provided on the memory card Netfinity 6000R Internal Hard Disk Drive HDD and External Storage Configur...

Page 61: ...ble bays 4 to 6 It includes a hot swap backplane and associated components for two cabling options Within the option are two 16 bit LVD SCSI cables One can be attached from the 3 pack Ultra160 Hot Swa...

Page 62: ...rs only two connectors may be utilized External connectors are 0 8 mm VHDCI 7 Netfinity ServeRAID 4H Ultra160 SCSI controller is powered by a 266MHz PowerPC 750 processor and provides 128 MB of batter...

Page 63: ...2 Netfinity 6000R ships without a keyboard or mouse 3 Installation within a rack requires optional keyboard tray P N 28L4707 stows in ready to use position 4 Advanced TrackPoint IV features are not a...

Page 64: ...s an external 0 8 mm VHDCI connector Select tape drive enclosure and supported adapter then use Appendix D Cables Storage Units Controllers to select an appropriate external cable 2 LVD support for LV...

Page 65: ...ures such as battery backed cache RAID protected internal hot swap storage and power protection with an APC Smart UPS Netfinity 6000R Sample Configurations Part Number Description Quantity 21RYMxx Net...

Page 66: ...65 Updated 28 02 01...

Page 67: ...ll speed L2 cache and 100 MHz access to memory and I O buses 3 Variable read rate Actual playback speed will vary and is often less than the maximum possible 4 Not available from IBM after this date B...

Page 68: ...P N 33L3113 3 Requires removal of standard memory DIMMs Part Number Memory Description1 Upgrade 10K2169 Compatible2 33L3067 Netfinity 64 MB 100 MHz ECC SDRAM RDIMM 33L3113 Netfinity 128 MB 100 MHz ECC...

Page 69: ...els 9 1 GB 1 1 1 18 2 GB 2 or 1 2 or 1 2 or 1 27 3 GB 3 3 3 36 4 GB 4 or 2 or 1 4 or 2 or 1 4 or 2 45 5 GB 5 5 5 54 6 GB 6 or 3 6 or 3 6 or 3 63 7GB 7 7 7 72 8 GB 8 or 4 or 2 8 or 4 or 2 8 or 4 81 9GB...

Page 70: ...SCSI port Select an optional SCSI controller then refer to Appendix D Cables Storage Units Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a su...

Page 71: ...are 0 8 mm VHDCI 7 Netfinity ServeRAID 4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery backed ECC cache with two internal and up to four extern...

Page 72: ...NetBAY3 with casters 2 Netfinity 7100 rack models are housed in a 19 rack mountable drawer and require one of the racks listed here Tower models require Netfinity 8Ux24D Tower to Rack Kit P N 37L6859...

Page 73: ...CSI Terminator2 16 LVD SE Ext Y N 10L7440 03K8705 10K2340 Media BayTray and LVD Cable Kit3 16 LVD Int Y N 03K8756 Note Netfinity 7100 includes an external 0 8 mm VHDCI connector 1 Non RAID Configurati...

Page 74: ...etfinity 7100 Netfinity 7100 Sample Configurations Part Number Description Quantity Usage 641YMxx Netfinity 7100 700MHz 2 MB Xeon 256 MB ECC Open 40X PCI 1 33L3067 Netfinity 64 MB 100 MHz ECC SDRAM RD...

Page 75: ...y 7600 Power Monitor Accessories for additional information 5 RAID adapter is equivalent to ServeRAID 4M Ultra160 SCSI Controller P N 37L6080 6 Variable read rate Actual playback speed will vary and i...

Page 76: ...for that row Example For 2 0 GB order 4 x P N 33L3113 plus 4 x P N 33L3115 3 Requires removal of standard RDIMMs Part Number Memory Description1 33L3113 Netfinity 128 MB 100 MHz ECC SDRAM RDIMM 33L31...

Page 77: ...kplane which limits Ultra160 HDDs to Ultra2 bus speeds Bay Form Factor Height Front Access Usage Part Number Description RPM Height Bays Supported Max Qty 89 mm 3 5 SL Yes Diskette Ultra160 Hard Disk...

Page 78: ...W auto ranging redundant power supplies each with it s own standard country power cord 5 Can be upgraded to a FAStT200 HA Storage Server through the addition of a FAStT200 Redundant RAID Controller P...

Page 79: ...tra160 connection External connectors are 0 8 mm VHDCI 7 Netfinity ServeRAID 4H Ultra160 SCSI Controller is powered by a 266 MHz PowerPC 750 processor and provides 128 MB of battery backed ECC cache w...

Page 80: ...pported devices 4 Netfinity 7600 ships without a keyboard or mouse 5 Installation within a rack requires optional keyboard tray P N 28L4707 stows in ready to use position 6 Installation within a rack...

Page 81: ...guration cables from Media Bay Tray and LVD Cable Kit P N 10K2340 which contains a single two drop mult mode LVD SCSI terminated cable If the standard cables are used for attachment to LVD devices sin...

Page 82: ...SDRAM RDIMM 4 33L3115 Netfinity 256MB 100MHz ECC SDRAM RDIMM 4 33L3117 Netfinity 512MB 100MHz ECC SDRAM RDIMM 4 4 GB Total System Memory 10K2332 700 MHz 2MB Upgrade II with Pentium III Xeon Processor...

Page 83: ...Xeon processors are supported on two 100 MHz P 6 CPU buses The recommended order of processor installation is Sockets A1 A3 A2 A4 B1 B3 B2 B4 2 Up to seven additional processors may be installed prov...

Page 84: ...quired for installation of processors 5 8 One Processor Mezzanine Board Two cache coherency filter modules 28L4730 economical 1X 256 K entries 28L4727 high performance 4X 1 M entries Filters may be us...

Page 85: ...of greater than 16 RDIMMs 3 Requires removal of standard memory 4 Models with 4 x 128 RDIMMs standard require Netfinity 8500R Memory Expansion Card P N 28L4454 for installation of greater than 16 RDI...

Page 86: ...Ultra2 bus speeds 2 Not supported by the onboard external SCSI port Select an optional SCSI controller then refer to Appendix D Cables Storage Units Controllers to confirm the controller supports the...

Page 87: ...is to be attached to an adapter the adapter must reside in slots 10 12 due to BIOS scanning sequences 4 Installation of a 33 MHz adapter into a Bus B or C 66 MHz slot will slow operation of all Bus B...

Page 88: ...ere xx represents a specific country code DK Denmark IS Israel IT Italy SD Saudi Arabia SA South Africa CH Switzerland UK UK EU Europe 10 Where xxx represents the appropriate country code as follows D...

Page 89: ...Storage Expansion Unit EL P N 03K8756 requires replacement of the standard single ended internal cables with one or more depending on configuration cables from Media Bay Tray and LVD Cable Kit P N 10...

Page 90: ...Storage Expansion Unit EL 1 External Tape Drive Enclosure 00N7990 40 80 B DLT Internal SCSI Tape Drive 2 Installs in NetMEDIA Enclosure 19K11xx Netfinity EXP300 Storage Expansion Unit 1 Provides addi...

Page 91: ...Required for greater than 4 processors 20L0247 Netfinity 256MB SDRAM ECC RDIMM II 16 Total of over 2GB of memory per node 28L4454 Netfinity 8500R Memory Expansion Card 2 Enables cache line interleavi...

Page 92: ...91 Updated 28 02 01...

Page 93: ...epresent all possible hard disk drive HDD configurations 1 Select a total storage row then select the quantity of HDDs from a column corresponding to the HDD of choice Total Internal Storage listed is...

Page 94: ...here xx represents a specific country code as follows 51 US English 52 European English 56 Danish English 57 Israel English 58 Italian English 59 South Africa English 60 Swiss English 63 UK English Li...

Page 95: ...desired select one from cable droup A EXP300 Two Independent SCSI Buses To configure as two independent 7 bay SCSI buses attach two external cables from two ServeRAID adapters in the same or separate...

Page 96: ...95 Updated 28 02 01...

Page 97: ...5707 18 2 GB 15K rpm FC Hot Swap HDD 15 000 SL 1 10 10 External Storage Expansion Unit Form Factor 19K11xx4 FAStT200 Storage Server1 2 3 Rack 3U 19K11xx5 FAStT200 HA Storage Server1 3 Rack 3U 19K1121...

Page 98: ...tion then becomes equivalent to the FAStT200 HA Storage Server 3 GBICs are not included Either Fibre Channel Long or Short Wave GBICs P N 03K9307 or 03K9308 respectively may be used 4 Where xx represe...

Page 99: ...ternal Storage listed is within 0 2 GB unless otherwise noted Part Number Description RPM Height Bays Supported Max Qty Supported 19K0652 18 2 GB 10K 4 FC Hot Swap HDD 10 000 SL 1 10 10 19K0653 36 4 G...

Page 100: ...ith a storage controller or external cables Select these items from the Fibre Channel Device Ports Reference Chart in the Fibre Array Solutions section 2 GBICs are not included Either Fibre Channel Lo...

Page 101: ...ection for GBIC Integrated port information 2 Where xx country publication and power cord codes as follows UK United Kingdom and Arabia DK Denmark IS Israel IT Italy SD Saudi Arabia SA South Africa SE...

Page 102: ...untry specific code as follows 37 US English 38 Euro English 39 Euro Spanish 41 Euro German 42 Denmark English 43 Israel English 44 Italy English 45 South Africa English 46 Switzerland English 48 Swit...

Page 103: ...Netfinity Enterprise Rack or Expansion Cabinet Netfinity Rack Netfinity NetBAY22 or 19 inch EIA D Industry Standard Rack Mounting rails are included with the controller For optimum performance no mor...

Page 104: ...ops Optional power supply P N 09L5403 available The 8 port switch is 1 U 1 U 1 75 in or 44 45 mm high and the 16 port switch is 2 U 1 U 1 75 in or 44 45 mm high P N 2019S08 P N 2019S16 SAN Fibre Chann...

Page 105: ...An optional short or long wave GBIC is required for all FAStT200 Storage Server and FAStT EXP500 storage connections GBICs are not depicted in these diagrams Other Fibre Channel devices may not requi...

Page 106: ...ICs are not depicted in these diagrams Other Fibre Channel devices may not require optional GBICs For specific requirements see the Fibre Device Ports Reference Fibre Channel Adapter1 FAStT500 Storage...

Page 107: ...20 M Ultra2 SCSI Cable Cable Group D Short Wave Fibre 36L9973 Netfinity Fibre Channel 1 M Cable 03K9306 Netfinity Fibre Channel 5 M Cable 03K9305 Netfinity Fibre Channel 25 M Cable Customer supplied s...

Page 108: ...High Density Connector 0 8 mm Very High Density Connection Interface VHDCI Cable Group A 0 8 mm to 0 8 mm 03K9310 Netfinity 2 M Ultra2 SCSI Cable 03K9311 Netfinity 4 2 M Ultra2 SCSI Cable 37L7101 Netf...

Page 109: ...NetBAY3 or in a tower configuration optional 8Ux28D Rack to Tower Kit P N 28L4705 must be installed 2 Netfinity 7000 M10 systems are rack mountable and ship without a keyboard In order to be utilised...

Page 110: ...NetBAY32 Netfinity 7100 NetBAY3 Casters P N 10L6913 Netfinity 5500 5500 Mxx Std NetBAY3 Add Options Single NetBay and Casters Max Configurations Add Options Up to Two Additional NetBAY3s P N 10L6912...

Page 111: ...Stationary 1700 1700 421Kg 928Kg 901Kg Rack Extension Kit1 P N 36L9703 Option P N 36L9703 Option P N 36L9702 Option NR NR Rack Attachment Kit P N 94G74463 Option P N 94G74463 Option NA NR Std NR Not R...

Page 112: ...oling blank filler panel kit P N 94G6670 should be placed on the front of any unused rack space If non IBM racks are to be used assure that both front and rear doors offer a minimum of 48 open area un...

Page 113: ...200 240V Single phase Front end PDU 1U 200 240V shared 20A mounts in sidewall compartment 3 IEC 320 C19 outlets 37L6887 NetBAY 3 phase Front end PDU 1U 200 415V shared 30A mounts in sidewall compartm...

Page 114: ...5 2794 110 Depth of Operational Clearance area F 51 2 51 2 Left Right sides of rack to Operational Clearance area G 762 30 914 36 Front of rack to Operational Clearance area H 610 24 660 26 Rear of r...

Page 115: ...Switch Tiering Switch Up to 4 or 8 Servers depending on switch type Console console cable set Console Switch Mounts to rear flanges Shares 3U space with display keyboard and tray Keyboard Tray Compone...

Page 116: ...115 Updated 28 02 01...

Page 117: ...A 1 1 10L74404 03K8756 01K1320 25 08 00 20 40GB DLT SCSI Tape Drive 8 133 mm 5 25 FH 20 40 1 5 3 Y Y 1 1 03K8705 03K8756 09N4040 20 40GB DLT Internal SCSI Tape Drive 8 133 mm 5 25 FH 20 40 1 5 3 N Y 1...

Page 118: ...reversed and screwed in from behind to secure the unit in a 930842x rack 10 NetMEDIA Systems Management Adapter P N 10L7113 may be installed in a NetMEDIA Storage Expansion Unit to provide repeater f...

Page 119: ...ince data compression is affected by many factors actual improvements may be more or less than 2X 2 Includes Fixed Shelf P N 94G7442 for installation in an IBM Rack or NetBAY22 3 Upgrade 33L4979 is an...

Page 120: ...119 Updated 28 02 01...

Page 121: ...ate UPS based on minimum and typical runtime estimates A maximum configuration load will result in minimum UPS runtime Typical loads are based on a production system running at approximately 70 of max...

Page 122: ...SU 5000RMB 37L6861 Total Load Watts Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes Runtime Minutes 200 22 38 62 130 45 104 240 250 17 28 43 104 34 84 2...

Page 123: ...CI Wide Ultra160 SCSI Adapter 19K4646 160 X F0 8 1 B A A Netfinity 6000R Ultra160 SCSI Onboard 160 X F0 8 1 A A Ultra2 SCSI Controllers Netfinity 3000 Model P Ns 780UExx and up Adapter 80 X F68 1 C C...

Page 124: ...ited by the enclosure or installed devices 14 Netfinity 7600 also includes a Netfinity ServeRAID 3HB Ultra2 SCSI Adapter P N 37L6086 See ServeRAID 3HB for connectivity requirements 15 Does not support...

Page 125: ...ble Adapter P N 37L1416 or directly to 1 or more Port Modules or Multiplexer Sets already attached to one of the cables A maximum of 4 Port Modules or Multiplexer Sets may be attached to single cable...

Page 126: ...per ibm com welcome myvc pl Consulting Engine for xSeries Netfinity includes Solution Sizing Tools download site www ibm com services uk portfolios servicepac ServicePac Services includes ServicePac S...

Page 127: ...include all documentation or functions Not all products are sold separately This publication originates in the United States IBM may not offer the products services or features discussed in this docu...

Reviews: