2
IBM xSeries 342: User’s Reference
Features and specifications
The following table provides a summary of the features and specifications for your
xSeries 342 server.
*KB equals approximately 1000 bytes. MB equals approximately 1000000 bytes. GB
equals approximately 1000000000 bytes.
Microprocessor:
•
Intel
®
Pentium
®
III
•
256 or 512 KB Level-2 cache
•
Supports up to two
microprocessors
Memory:
•
Maximum: 4 GB
•
Type: ECC, SDRAM, PC133,
registered DIMMs
•
Four slots (two-way interleaved)
Drives standard:
•
Diskette: 1.44 MB
•
CD-ROM: 24X IDE
Expansion bays:
•
Hot-swap: Three slim high
•
Non-hot-swap: Two 5.25-inch,
replaceable with a three slim-high
hot-swap drive expansion option
PCI expansion slots:
•
One 33 MHz/32-bit
•
Two 33 MHz/64-bit
•
Two 66 MHz/64-bit
Hot-swap power supplies:
270 Watt (115-230 V ac)
•
Minimum: One
•
Maximum: Two - the second power
supply provides redundant power
Video:
•
S3 video controller
•
Compatible with SVGA and VGA
•
8 MB video memory
Size (rack model 3U):
•
Height: 128 mm (5 in.)
•
Depth: 695 mm (27.3 in.)
•
Width: 440 mm (17.3 in.)
•
Weight: 21.3 to 29.5 Kg (47 to 65
lb) depending upon configuration
Integrated functions:
•
Dual channel Ultra160 SCSI
controller
•
One 10BASE-T, 100BASE-TX,
100BASE-FX, Intel Ethernet
controller with Alert on LAN
™
and
Wake on LAN
®
support
•
Two serial ports
•
Two Universal Serial Bus ports
•
Keyboard port
•
Mouse port
•
Video port
•
Integrated System Management
(ISM) Processor
—
Two ISM (RJ-45) connectors
—
One system management
Serial C port
Acoustical noise emissions:
•
Sound power, idling (open bay):
6.6 bel maximum
•
Sound power, operating: 6.8 bel
maximum
•
Sound pressure, operating: 53
dBa maximum
Redundant cooling:
Three hot-swap fans
Environment:
•
Air temperature:
—
Server on: 10
°
to 35
°
C
(50
°
to 95
°
F). Altitude: 0 to
914 m (2998 ft)
—
Server on: 10
°
to 32
°
C
(50
°
to 89.6
°
F). Altitude:
914 m (2998 ft) to 2133 m
(6998 ft)
—
Server off: 10
°
to 43
°
C
(50
°
to 109.4
°
F).
Maximum altitude: 2133 m
(6998 ft)
•
Humidity:
—
Server on: 8% to 80%
—
Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
•
Minimum configuration: 375 Btu
(110 watts)
•
Maximum configuration: 1300
Btu (380 watts)
Electrical input:
•
Sine-wave input (50-60 Hz)
required
•
Input voltage low range:
—
Minimum: 100 V ac
—
Maximum: 127 V ac
•
Input voltage high range:
—
Minimum: 200 V ac
—
Maximum: 240 V ac
•
Input kilovolt-amperes (kVA)
approximately:
—
Minimum: 0.08 kVA (0.076
kW)
Table 1. Features and Specifications.