100
IBM xSeries 130: User’s Reference
075
Microprocessor
Failed
VRM corresponding to Microprocessor in socket
xyz
is defective
(where
xyz
identifies the microprocessor whose
VRM is causing the error message)
Replace the VRM.
If the problem remains,
call for service.
VRM corresponding to Microprocessor in socket ID
xyz
is not installed
(where
xyz
identifies the microprocessor whose
VRM is causing the error message)
Install a VRM.
If the problem persists,
call for service.
175
System thermal
Failed
Fan #
n
(where
n
is the number of the failing fan)
Replace the indicated
fan.
Temperature sensed on processor board is out of
range
Call for service.
180
Status display
Failed
Any failure message
Call for service.
201
System memory
Failed
DIMMs in location DIMM
n
(where
n
is the number of the socket that contains
the failing DIMM)
1.
Reseat the failing
DIMM.
2.
If the problem
remains, replace
the DIMM.
If the problem
persists, call for
service.
Test setup error: Corrupt BIOS in ROM
If your appliance server
does not have the latest
level BIOS installed,
update the BIOS to the
latest level.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS, information in
BIOS is not as expected
Table 15. Diagnostic error messages.
Code
Function
Result
Text message
Action
Summary of Contents for eServer 130 xSeries
Page 1: ...User s Reference xSeries 130 ...
Page 2: ......
Page 3: ...IBM IBM xSeries 130 User s Reference ...
Page 8: ...vi IBM xSeries 130 User s Reference ...
Page 14: ...xii IBM xSeries 130 User s Reference ...
Page 46: ...32 IBM xSeries 130 User s Reference ...
Page 58: ...44 IBM xSeries 130 User s Reference ...
Page 62: ...48 IBM xSeries 130 User s Reference ...
Page 96: ...82 IBM xSeries 130 User s Reference ...
Page 136: ...122 IBM xSeries 130 User s Reference ...
Page 154: ...140 IBM xSeries 130 User s Reference ...
Page 155: ......
Page 156: ...IBM Part Number 32P0093 Printed in U S A 32P 93 ...