Fan error messages
Message
Action
Fan
″
X
″
failure
(level-critical; fan
″
X
″
had a
failure)
1.
Check connections to fan
″
X
″
2. Replace fan
″
X
″
Fan
″
X
″
fault
(level-critical; fan
″
X
″
beyond
recommended RPM range)
1.
Check connections to fan
″
X
″
2. Replace fan
″
X
″
Fan
″
X
″
Outside Recommended Speed
Action
1.
Replace Fan
″
X
″
Power error messages
Message
Action
Power supply
″
X
″
current share fault
(level-critical; excessive current demand on
power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
DC good fault
(level-critical; power good signal not detected
for power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
temperature fault
1.
Replace power supply
″
X
″
Power supply
″
X
″
removed
1.
No action required - information only
Power supply
″
X
″
fan fault
(level-critical;
fan fault in power supply
″
X
″
)
1.
Replace power supply
″
X
″
Power supply
″
X
″
12V fault
(level-critical;
overcurrent condition detected)
1.
See “Power checkout” on page 19.
Power supply
″
X
″
3.3V fault
(level-critical;
3.3V power supply
″
X
″
had an error)
1.
See “Power checkout” on page 19.
Power supply
″
X
″
5V fault
(level-critical; 5V
power supply
″
X
″
had an error)
1.
See “Power checkout” on page 19.
System running non-redundant power
(level-non-critical; system does not have
redundant power)
1.
Add another power supply
2. Remove options from system
3. System can continue to operate without redundancy protection if
1
and
2
above are not followed.
System under recommended voltage for
″
X
″
(level-warning; indicated voltage supply
under nominal value; value for
″
X
″
can be
+12, -12, or +5)
1.
Check connections to power subsystem
2. Replace power supply
3. Replace power backplane
System shutdown
Refer to the following tables when experiencing system shutdown related to voltage
or temperature problems.
100
Hardware Maintenance Manual: xSeries 342 Type 8669
Summary of Contents for 8669 - Eserver xSeries 342
Page 1: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 10: ...viii Hardware Maintenance Manual xSeries 342 Type 8669...
Page 32: ...22 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 42: ...32 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 86: ...76 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 114: ...104 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 129: ...Related service information 119...
Page 130: ...120 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 131: ...Related service information 121...
Page 132: ...122 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 133: ...Related service information 123...
Page 134: ...124 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 135: ...Related service information 125...
Page 136: ...126 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 146: ...136 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 147: ...Related service information 137...
Page 148: ...138 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 155: ......
Page 156: ...Part Number 24P2922 1P P N 24P2922...