Error Code/Symptom
FRU/Action
217-XXX-003
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 4
217-XXX-004
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 5
217-XXX-005
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 6
264-XXX-0NN
(Failed Tape Drive test)
1.
Tape Cartridge, if user executed the Read/Write Tape Drive test
(failure code of XXX = 256)
2. SCSI or Power Cable connected to tape drive with SCSI ID NN.
3. Tape Drive with SCSI ID NN. (Refer to the Help and Service
Information appendix of the tape drive’s User Guide.)
4. System Board or SCSI Controller. (Run SCSI Controller Diagnostic
to determine if the SCSI bus is functioning properly.)
264-XXX-999
(Errors on multiple tape
drives, see error text for more info)
1.
See error messages/text in the PC Doctor error log for detailed
information on each individual tape drive error.
301-XXX-000
(Failed Keyboard test)
1.
Keyboard
405-XXX-000
(Failed Ethernet test on
controller on the System Board)
1.
Verify that Ethernet is not disabled in BIOS.
2. System Board
405-XXX-00N
(Failed Ethernet test on
adapter in PCI slot N)
1.
Adapter in PCI slot N.
2. System Board
415-XXX-000
(Failed Modem test)
1.
Cable
Note:
Ensure modem is present and attached to server.
2. Modem
3. System Board
Error symptoms
Error Symptom
FRU/Action
CD is not working properly.
1.
Clean the CD.
2. Run CD-ROM diagnostics
3. CD-ROM Drive
CD-ROM drive tray is not working.
(The
server must be powered-on)
1.
Insert the end of a paper clip into the manual tray-release
opening.
2. Run CD-ROM diagnostics
3. CD-ROM Drive
CD-ROM drive is not recognized
.
1.
Run Configuration/Setup, enable primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
4. System Board
5. Run CD-ROM diagnostics
6. CD-ROM Drive
Symptom-to-FRU index
91
Summary of Contents for 8669 - Eserver xSeries 342
Page 1: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 10: ...viii Hardware Maintenance Manual xSeries 342 Type 8669...
Page 32: ...22 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 42: ...32 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 86: ...76 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 114: ...104 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 129: ...Related service information 119...
Page 130: ...120 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 131: ...Related service information 121...
Page 132: ...122 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 133: ...Related service information 123...
Page 134: ...124 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 135: ...Related service information 125...
Page 136: ...126 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 146: ...136 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 147: ...Related service information 137...
Page 148: ...138 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 155: ......
Page 156: ...Part Number 24P2922 1P P N 24P2922...