Error Code/Symptom
FRU/Action
166-400-000 System Management: Failed
System management hardware on system
board failed) (ISMP Self Test Result failed
tests: x where x = Flash, RAM, or ROM.)
1. Re-flash or Update firmware for ISMP
2. System board
180-XXX-000
(Diagnostics LED failure)
1.
Run Diagnostic LED test for the failing LED.
180-XXX-001
(Failed Front LED panel test)
1.
Operator Information Panel
2. Power Switch Assembly
3. System Board
180-XXX-002
(Failed Diagnostics LED
Panel test)
1.
System Board
180-361-003
(Failed Fan LED test)
1.
Fan(s)
2. System Board
180-XXX-003
(Failed System Board LED
test)
1.
System Board
180-XXX-005
(Failed SCSI Backplane LED
test)
1.
SCSI Backplane
2. SCSI Backplane Cable
3. System Board
201-XXX-0NN
(Failed Memory test, see
″
Memory Settings
″
on page 25)
1.
DIMM Location slots 1-4 where NN = DIMM location.
Note:
NN=1=DIMM 1 =2=DIMM 2 =3=DIMM 3 =4=DIMM 4
2. System Board
201-XXX-999
(Multiple DIMM failure, see
error text)
1.
See error text for failing DIMMs
2. System Board
202-XXX-001
(Failed System Cache test)
1.
VRM 1
2. Microprocessor 1
202-XXX-002
(Failed System Cache test)
1.
VRM 2
2. Microprocessor 2
206-XXX-000
(Failed Diskette Drive test)
1.
Cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1.
CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
217-198-XXX
(Could not establish drive
parameters)
1.
Check cable and termination
2. SCSI Backplane
3. Fixed Disk
217-XXX-000
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 2
217-XXX-002
(Failed BIOS Fixed Disk test)
Note:
If RAID is configured, the fixed disk
number refers to the RAID logical array
1.
Fixed Disk 3
90
Hardware Maintenance Manual: xSeries 342 Type 8669
Summary of Contents for 8669 - Eserver xSeries 342
Page 1: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 342 Type 8669 ERserver...
Page 10: ...viii Hardware Maintenance Manual xSeries 342 Type 8669...
Page 32: ...22 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 42: ...32 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 86: ...76 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 114: ...104 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 129: ...Related service information 119...
Page 130: ...120 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 131: ...Related service information 121...
Page 132: ...122 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 133: ...Related service information 123...
Page 134: ...124 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 135: ...Related service information 125...
Page 136: ...126 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 146: ...136 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 147: ...Related service information 137...
Page 148: ...138 Hardware Maintenance Manual xSeries 342 Type 8669...
Page 155: ......
Page 156: ...Part Number 24P2922 1P P N 24P2922...