following:
IBM Netfinity Setup - © IBM Corporation 1998
<F1> Help < > < > Move
<Esc> Exit <Enter> Select
↑
↓
•
•
•
•
•
•
•
•
System Summary
System Information
Devices and I/O Ports
Date and Time
System Security
Start Options
Advanced Setup
Error Logs
Save Settings
Restore Settings
Load Default Settings
Exit Setup
Configuration/Setup Utility
Notes:
1.
You can press F1 to display Help information for a selected menu item.
2.
The choices on some menus might differ slightly, depending on the BIOS
version in the server.
Descriptions of the choices available from the main menu are as follows:
v
System Summary
Select this choice to display configuration information. This includes the type
and speed of the microprocessors and the amount of memory installed.
Changes that you make to configuration settings appear on this summary
screen. You cannot edit the fields.
This choice appears on both the full and limited Configuration/Setup Utility
menus.
v
System Information
Select this choice to display information about the server. Changes that you
make on other menus might appear on this summary screen. You cannot edit
any fields. The System Information choice appears only on the full
Configuration/Setup Utility main menu.
– Product Data
Select this choice to view system information, such as the machine type and
model, the server serial number, and the revision level or issue date of the
BIOS stored in the flash electronically erasable programmable ROM
(EEPROM).
– System Card Data
Select this choice to view vital product data (VPD) for some server
components.
v
Devices and I/O Ports
Select this choice to view or change the assignments for devices and
input/output ports. This choice appears only on the full Configuration/Setup
Utility main menu.
v
Date and Time
Select this choice to set the system date and time and to change the system time
sent to the Advanced System Management Processor (service processor) when
the server is started. This choice appears only on the full Configuration/Setup
Utility main menu.
The system time is in a 24-hour format: hour:minute:second.
You can set a time delta to be added or subtracted from the system time that is
sent to the service processor (Advanced System Management Processor) each
32
Hardware Maintenance Manual: Netfinity 7100 – Type 8666
Summary of Contents for 866631Y - Netfinity 7100 - 8666
Page 1: ...Hardware Maintenance Manual Netfinity 7100 Type 8666 IBM ...
Page 2: ......
Page 3: ...Hardware Maintenance Manual Netfinity 7100 Type 8666 IBM ...
Page 10: ...viii Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 86: ...76 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 118: ...108 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 128: ...118 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 154: ...144 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 172: ...162 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 173: ...Related service information 163 ...
Page 174: ...164 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 175: ...Related service information 165 ...
Page 176: ...166 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 177: ...Related service information 167 ...
Page 178: ...168 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 188: ...178 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 189: ...Related service information 179 ...
Page 190: ...180 Hardware Maintenance Manual Netfinity 7100 Type 8666 ...
Page 197: ......