Note:
See Chapter 8, “Parts listing, Type 8482 and 8487,” on page 99 to determine which components are
replaceable by the customer (CRU), and which components must be replaced by a field service technician (FRU).
Error code/symptom
FRU/action
189
(An attempt was made to access the
server with invalid passwords)
v
Run the Configuration/Setup Utility program, and enter the
administrator password.
201
(Memory test error.) If the server does not
have the latest level of BIOS installed,
update the BIOS to the latest level and run
the diagnostic program again.
1.
DIMM
2. System board
289
(DIMM disabled by POST or user)
1.
Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2. Disabled DIMM, if not disabled by user.
3. System board
301
(Keyboard or keyboard controller error)
1.
Keyboard
2. System board
303
(Keyboard controller error)
v
System board
602
(Invalid diskette boot record)
1.
Diskette
2. Diskette drive
3. Cable
4. System board
604
(Diskette drive error)
1.
Run the Configuration/Setup Utility program.
2. Diskette drive.
3. Cable.
4. System board.
662
(Diskette drive configuration error)
1.
Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
962
(Parallel port error)
1.
Disconnect the external cable on the parallel port.
2. Run the Configuration/Setup Utility program.
3. System board.
1162
(Serial port configuration conflicts)
1.
Run the Configuration/Setup Utility program
and ensure that the
IRQ and I/O port assignments needed by the serial port are
available.
2. If all interrupts are being used by adapters, remove an adapter or
force other adapters to share an interrupt.
1762
(Hard disk configuration error)
1.
Hard disk drive.
2. Hard disk drive cables.
3. Run the Configuration/Setup Utility program.
4. SCSI backplane.
5. System board.
1800
(No more hardware interrupts available for
PCI adapter)
1.
Run the Configuration/Setup Utility program.
2. Remove adapter.
Chapter 7. Symptom-to-FRU index
81
Summary of Contents for 84875MU
Page 1: ...xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 6: ...iv xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 10: ...viii xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 22: ...12 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 68: ...58 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 86: ...76 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 127: ...Appendix B Related service information 117...
Page 128: ...118 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 129: ...Appendix B Related service information 119...
Page 130: ...120 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 131: ...Appendix B Related service information 121...
Page 132: ...122 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 133: ...Appendix B Related service information 123...
Page 143: ...Appendix B Related service information 133...
Page 144: ...134 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 145: ...Appendix B Related service information 135...
Page 146: ...136 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 150: ...140 xSeries 206 Type 8482 and 8487 Hardware Maintenance Manual and Troubleshooting Guide...
Page 159: ......
Page 160: ...Part Number 49Y0092 Printed in USA 1P P N 49Y0092...