E-7
Three-Digit Display Numbers
597
OCS software being configured.
598
OCS hosts being configured during system reboot.
599
Configuring FDDI data link control.
600
Starting network boot portion of /sbin/rc.boot
602
Configuring network parent devices.
603
/usr/lib/methods/defsys, /usr/lib/methods/cfgsys, or
/usr/lib/methods/cfgbus failed.
604
Configuring physical network boot device.
605
Configuration of physical network boot device failed.
606
Running /usr/sbin/ifconfig on logical network boot device.
607
/usr/sbin/ifconfig failed.
608
Attempting to retrieve the client.info file with tftp. Note that a flashing 608
indicates multiple attempt(s) to retrieve the client_info file are occurring.
609
The client.info file does not exist or it is zero length.
610
Attempting remote mount of NFS file system.
611
Remote mount of the NFS file system failed.
612
Accessing remote files; unconfiguring network boot device.
614
Configuring local paging devices.
615
Configuration of a local paging device failed.
616
Converting from diskless to dataless configuration.
617
Diskless to dataless configuration failed.
618
Configuring remote (NFS) paging devices.
619
Configuration of a remote (NFS) paging device failed.
620
Updating special device files and ODM in permanent filesystem with data
from boot RAM filesystem.
622
Boot process configuring for operating system installation.
77c
Progress indicator. A 1.0 GB 16-bit SCSI disk drive being identified or
configured.
700
Progress indicator. A 1.1 GB 8-bit SCSI disk drive being identified or
configured.
701
Progress indicator. A 1.1 GB 16-bit SCSI disk drive is being identified or
configured.
702
Progress indicator. A 1.1 GB 16-bit differential SCSI disk drive is being
identified or configured.
703
Progress indicator. A 2.2 GB 8-bit SCSI disk drive is being identified or
configured.
704
Progress indicator. A 2.2 GB 16-bit SCSI disk drive is being identified or
configured.
705
The configuration method for the 2.2 GB 16-bit differential SCSI disk drive is
being run. If an irrecoverable error occurs, the system halts.
706
Progress indicator. A 4.5 GB 16-bit SCSI disk drive is being identified or
configured.
707
Progress indicator. A 4.5 GB 16-bit differential SCSI disk drive is being
identified or configured.
708
Progress indicator. A L2 cache is being identified or configured.
710
POWER GXT150M graphics adapter being identified or configured.
711
Unknown adapter being identified or configured.
712
Graphics slot bus configuration is executing.
713
The IBM ARTIC960 device is being configured.
714
A video capture adapter is being configured.
715
The Ultimedia Services audio adapter is being configured. This LED
displays briefly on the panel.
720
Unknown read/write optical drive type being configured.
721
Unknown disk or SCSI device being identified or configured.
Summary of Contents for 7013 J Series
Page 1: ...7013 J Series Operator Guide SA23 2724 02 ...
Page 12: ...xii Operator Guide ...
Page 16: ...xvi Operator Guide ...
Page 18: ...xviii Operator Guide ...
Page 32: ...1 14 Operator Guide ...
Page 80: ...2 48 Operator Guide ...
Page 166: ...5 14 Operator Guide ...
Page 186: ...7 4 Operator Guide ...
Page 226: ...9 28 Operator Guide ...
Page 258: ...B 8 Operator Guide ...
Page 268: ...D 4 Operator Guide ...