9-24
Operator Guide
RS-485 Cables Interconnection
The RS-485 cables interconnection must be performed from unit to unit.
1. Insert a terminator plug on the upper 6 pins mini connector located on the system interface
board installed in the base unit. (This connector is marked ‘‘IN’’ on the system interface
board.)
2. Connect one of the two connectors of the RS-485 cable (it is not important which one) to the
lower 6 pins mini connector located on the system interface board installed in the base unit.
(This connector is marked ‘‘OUT’’ on the system interface board.)
3. Connect the other connector of the RS-485 cable used in the previous step to the upper
6-pin mini connector located on the required system interface board installed in the
expansion unit.
4. Insert a terminator plug in the lower 6 pins mini connector located on the required system
interface board installed in the expansion unit (the one nearest the center of the expansion
unit).
The following figure shows an example of RS-485 connection between the base and the
expansion unit.
Terminator
Required
Optional
RS-485 Cable