v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8849
or
Type
8491
server,”
on
page
61
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
005-xxx-000
Failed
video
test.
1.
Reseat
the
video
adapter,
if
one
is
installed.
2.
(Trained
service
technician
only)
Replace
the
system
board.
011-xxx-000
Failed
COM1
serial
port
test.
1.
Check
the
loopback
plug
that
is
connected
to
the
externalized
serial
port.
2.
Check
the
cable
from
the
externalized
serial
port
to
the
system
board.
3.
(Trained
service
technician
only)
Replace
the
system
board.
020-xxx-000
Failed
PCI
Interface
test.
1.
Reseat
the
riser-card
assembly.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Riser-card
assembly
b.
(Trained
service
technician
only)
System
board.
035-002-0nn
ServeRAID
interface
timeout.
1.
Make
sure
that
the
ServeRAID
controller
is
configured
correctly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
see
the
ServeRAID
adapter
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
Hot-swap
SAS/SATA
hard
disk
drive
backplane
cables
b.
ServeRAID
adapter
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
035-253-0nn
ServeRAID
controller
0nn
initialization
failure;
0nn
=
the
controller
number.
1.
The
ServeRAID
controller
might
not
be
configured
correctly.
See
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Reseat
the
following
components:
a.
Hot-swap
SAS/SATA
hard
disk
drive
backplane
cables
b.
ServeRAID
adapter
3.
Replace
the
components
listed
in
step
2
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
Chapter
2.
Diagnostics
41
Summary of Contents for 306m - eServer xSeries - 8849
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 84: ...68 IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 141: ......
Page 142: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...