![IBM 306m - eServer xSeries - 8849 Service Manual Download Page 41](http://html2.mh-extra.com/html/ibm/306m-eserver-xseries-8849/306m-eserver-xseries-8849_service-manual_3375798041.webp)
General
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8849
or
Type
8491
server,”
on
page
61
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
A
cover
lock
is
broken,
an
LED
is
not
working,
or
a
similar
problem
has
occurred.
If
the
part
is
a
CRU,
replace
it.
If
the
part
is
a
FRU,
the
part
must
be
replaced
by
a
trained
service
technician.
Hard
disk
drive
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8849
or
Type
8491
server,”
on
page
61
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
Not
all
drives
are
recognized
by
the
hard
disk
drive
diagnostic
test
(the
Fixed
Disk
test).
Remove
the
drive
indicated
on
the
diagnostic
tests;
then,
run
the
hard
disk
drive
diagnostic
test
again.
If
the
remaining
drives
are
recognized,
replace
the
drive
that
you
removed
with
a
new
one.
The
server
stops
responding
during
the
hard
disk
drive
diagnostic
test.
Remove
the
hard
disk
drive
that
was
being
tested
when
the
server
stopped
responding,
and
run
the
diagnostic
test
again.
If
the
hard
disk
drive
diagnostic
test
runs
successfully,
replace
the
drive
that
you
removed
with
a
new
one.
A
hard
disk
drive
was
not
detected
while
the
operating
system
was
being
started.
Reseat
all
hard
disk
drives
and
cables;
then,
run
the
hard
disk
drive
diagnostic
tests
again.
A
hard
disk
drive
passes
the
diagnostic
Fixed
Disk
Test
but
the
problem
remains.
Run
the
diagnostic
SCSI
Fixed
Disk
Test
(see
“Running
the
diagnostic
programs”
on
page
38).
Note:
This
test
is
not
available
on
servers
that
have
RAID
arrays
or
servers
that
have
SATA
hard
disk
drives.
Use
the
Fixed
Disk
Test
for
SATA
hard
disk
drives
or
servers
that
have
RAID
arrays.
Chapter
2.
Diagnostics
25
Summary of Contents for 306m - eServer xSeries - 8849
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 84: ...68 IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 141: ......
Page 142: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...