![IBM 306m - eServer xSeries - 8849 Service Manual Download Page 70](http://html2.mh-extra.com/html/ibm/306m-eserver-xseries-8849/306m-eserver-xseries-8849_service-manual_3375798070.webp)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8849
or
Type
8491
server,”
on
page
61
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
System
is
over
recommended
voltage
for
+1.5V
CPU
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
c.
(Trained
service
technician
only)
Power
supply
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Microprocessor
System
is
over
recommended
voltage
on
+3.3V
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
is
under
recommended
voltage
on
VRM
1.
1.
(Trained
service
technician
only)
Reseat
the
microprocessor.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
System
is
under
recommended
voltage
for
+1.5V
CPU
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
Microprocessor
b.
(Trained
service
technician
only)
System
board
c.
(Trained
service
technician
only)
Power
supply
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Microprocessor
System
is
under
recommended
voltage
on
+3.3V
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
System
log
75%
full
Clear
the
current
logs.
System
log
cleared
Information
only.
System
memory
error
1.
Reseat
the
DIMMs.
2.
Replace
the
memory.
System
over
recommended
voltage
for
+12v.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
System
board
b.
(Trained
service
technician
only)
Power
supply
2.
(Trained
service
technician
only)
Replace
the
system
board.
54
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Summary of Contents for 306m - eServer xSeries - 8849
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 84: ...68 IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 141: ......
Page 142: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...