69
Version 20.01, 20-July-2020
13.3. IBC Aerofix / AeroFlat Stiction Log
IBC AeroFix / AeroFlat flat-roof system
Test record
Determination of stiction coefficients
CUSTOMER INFORMATION
Name
Phone
Company
Mobile
Street / No.
Fax
Post
code/city
CONSTRUCTION PROJECT
Customer
name
Phone
Street / No.
Mobile
Post
code/city
Fax
Com.:
TEST PROCEDURE
The test specimen (10 kg on IBC stiction gauge)
is placed onto the roof membrane with the
appropriate protective matting. After the defined
waiting period (around 30 seconds) has elapsed,
parallel force is applied centrally to the test
specimen using the tension spring, and then
measured using the spring scale. It is important
that the force be applied evenly. The maximum
force that can be applied before the test
specimen begins to move indicates the
coefficient of friction.
The tests are to be performed in accordance with the October 2004 edition of DIN EN ISO 8295, Plastics -
Films and sheeting - Determining coefficients of friction.
A total of 10 tests are to be carried out: five dry, five wet. The tests are to be distributed evenly across the roof
surface.
Visually dissimilar roof areas are to be tested separately from one another. The tests are to be repeated
accordingly.
Before testing begins, the roof membrane areas where measurements are being taken should be cleaned.
Static friction coefficient µ = F /G
Summary of Contents for AeroFix 10-EW
Page 1: ...1 Installation instructions IBC AeroFix AeroFlat Version 20 01 Date 20 July 2020...
Page 9: ...9 Version 20 01 20 July 2020 4 2 AeroFlat Parallel to the roof Fig 6 AeroFlat...
Page 17: ...17 Version 20 01 20 July 2020 Fig 15 Installation base rails Fig 16 Installation base rails...
Page 42: ...42 Version 20 01 20 July 2020 Fig 61 Wind plate assembly Fig 62 Fixation wind plate...
Page 53: ...53 Version 20 01 20 July 2020 Fig 81 Schematic system dimensions...
Page 68: ...68 Version 20 01 20 July 2020...
Page 71: ...71 Version 20 01 20 July 2020 13 4 Checklist IBC AeroFix...
Page 72: ...72 Version 20 01 20 July 2020...