56
Version 20.01, 20-July-2020
10. System security device
For a roof inclination > 3° it is an additional system security device in the direction of the roof pitch
necessary.
For a roof inclination ≤ 3° it is an additional system security device recommended. With the
anti-slip safety device, the module arrays are connected to each other via the ridge. Alternatively, the anti-
slip syftey device can be attached at the building. The fastening to the building must be planned and
statically tested by the customer. The anti-slip safety device is then attached every second to fourth row.
Damage to the roof cladding from the anti-slip safety device can be prevented in the long-term through
suitable measures by the customer.
Mounting the anti-slip safety device. The perforated tape links the ground rails over the ridge.
Fig. 86 Cross-mounted anti-slip safety device AeroFix
Fig. 87 Longitudinally mounted anti-slip saftey device AeroFix
Summary of Contents for AeroFix 10-EW
Page 1: ...1 Installation instructions IBC AeroFix AeroFlat Version 20 01 Date 20 July 2020...
Page 9: ...9 Version 20 01 20 July 2020 4 2 AeroFlat Parallel to the roof Fig 6 AeroFlat...
Page 17: ...17 Version 20 01 20 July 2020 Fig 15 Installation base rails Fig 16 Installation base rails...
Page 42: ...42 Version 20 01 20 July 2020 Fig 61 Wind plate assembly Fig 62 Fixation wind plate...
Page 53: ...53 Version 20 01 20 July 2020 Fig 81 Schematic system dimensions...
Page 68: ...68 Version 20 01 20 July 2020...
Page 71: ...71 Version 20 01 20 July 2020 13 4 Checklist IBC AeroFix...
Page 72: ...72 Version 20 01 20 July 2020...