38
Version 20.01, 20-July-2020
The middle and outer clamp are delivered pre-
assembled.
The middle clamp G3 covers a clamping area of
30-50 mm.
However the outer clamp G3 must be ordered for
each module height.
G3 Middle and outside clamp
The middle clamp G4 covers a clamping area of
33-46 mm.
The EC adapter is installed with the middle clamp
G4 or G3 and replaces the traditional outer clamp.
G4 middle clamp and EC adapter
Important information:
Depending on the height of the module frame, a different version of the outer clamp G3 will be required.
The EC adapter for G4 middle clamp covers only the frame sizes 33, 35, 38, 40, 45 and 46mm.
The tightening torque of the clamps is 15 Nm!
Do not use a ratchet or a wrench with high leverage as the maximum tightening torque could easily be
exceeded.
Please only use a Torx screwdriver with T-handle or cordless screwdrivers with the appropriate torque
settings.
The middle and outer clamps G3 can be inserted into the supports directly from above where required.
1. Insert 2. Press 3. Fixed
Fig. 53: Inserting the middle clamp G3
Summary of Contents for AeroFix 10-EW
Page 1: ...1 Installation instructions IBC AeroFix AeroFlat Version 20 01 Date 20 July 2020...
Page 9: ...9 Version 20 01 20 July 2020 4 2 AeroFlat Parallel to the roof Fig 6 AeroFlat...
Page 17: ...17 Version 20 01 20 July 2020 Fig 15 Installation base rails Fig 16 Installation base rails...
Page 42: ...42 Version 20 01 20 July 2020 Fig 61 Wind plate assembly Fig 62 Fixation wind plate...
Page 53: ...53 Version 20 01 20 July 2020 Fig 81 Schematic system dimensions...
Page 68: ...68 Version 20 01 20 July 2020...
Page 71: ...71 Version 20 01 20 July 2020 13 4 Checklist IBC AeroFix...
Page 72: ...72 Version 20 01 20 July 2020...