CC-Link
X-SEL I/O parameter
No. Parameter
name
Default
(reference)
Input
range
Setting Remarks
1
I/O port assignment type
1
0 – 20
0
0: Fixed assignment
1: Automatic assignment (Priority: slot 1
—
)
* The ports only in the continuous
installation range from slot 1 are
assigned for safety.)
2 Standard
I/O:
Input port start No. (I/O1)
000
-1 – 599
000
0 + (multiples of 8) (Invalid for negative values)
3 Standard
I/O:
Output port start No. (I/O1)
300
-1 – 599
300
300 + (multiples of 8)
(Invalid for negative values)
4
Expansion I/O1 fixed assignment
time: Input port start No. (I/O2)
-1
-1 – 599
32
0 + (multiples of 8) (Invalid for negative values)
(Slot next to the standard I/O)
5
Expansion I/O1 fixed assignment
time: Output port start No. (I/O2)
-1
-1 – 599
316
300 + (multiples of 8)
(Invalid for negative values)
6
Expansion I/O2 fixed assignment
time: Input port start No. (I/O3)
-1
-1 – 599
048
0 + (multiples of 8) (Invalid for negative values)
7
Expansion I/O2 fixed assignment
time: Output port start No. (I/O3)
-1
-1 – 599
332
300 + (multiples of 8)
(Invalid for negative values)
8
Expansion I/O3 fixed assignment
time: Input port start No. (I/O4)
-1
-1 – 599
064
0 + (multiples of 8) (Invalid for negative values)
9
Expansion I/O3 fixed assignment
time: Output port start No. (I/O4)
-1
-1 – 599
348
300 + (multiples of 8)
(Invalid for negative values)
10 Standard I/O error monitoring
(I/O1)
2
0 – 5
1
11 Expansion I/O1 error monitoring
(I/O2)
0
0 – 5
2
12 Expansion I/O2 error monitoring
(I/O3)
0
0 – 5
2
13 Expansion I/O3 error monitoring
(I/O4)
0
0 – 5
2
0: Non-monitoring
1: Monitoring
2: Monitoring (Non-monitoring of 24V I/O
power related errors)
(Main application of Ver. 0.55 or later)
3: Monitoring (Monitoring of 24V I/O power
related errors only)
(Main application of Ver. 0.55 or later)
14 Network I/F card remote:
Number of ports used for input
64
0 – 256
0
Multiples of 16
15 Network I/F card remote:
Number of ports used for output
64
0 – 256
0
Multiples of 16
(I/O1) to (I/O4) indicate the slot numbers.
42
Summary of Contents for X-SEL-J*-1-CC0 series
Page 1: ...CC Link Instruction Manual Ver 5 0 X SEL RCS C E Con IAI Corporation...
Page 16: ...CC Link 9...
Page 25: ...CC Link 18...
Page 50: ...CC Link 43...