CC-Link
(2) Factory-configured
parameters
A: X-SEL-K
□
-
□
-CC1-
□
B: X-SEL-K
□
-
□
-CC2-
□
C: X-SEL-K
□
-
□
-CC3-
□
Set
value
No. Parameter
name
Input
range
A B C
Remarks
1
I/O port assignment type
0 – 20
0
0
0
0: Fixed assignment
1: Automatic assignment (Priority: slot 1
—
)
* The ports only in the continuous installation
range from slot 1 are assigned for safety.)
2 Standard
I/O:
Input port start No. (I/O1)
-1 – 599
-1
-1
-1
0 + (multiples of 8) (Invalid for negative values)
3 Standard
I/O:
Output port start No. (I/O1)
-1 – 599
-1
-1
-1
300 + (multiples of 8)
(Invalid for negative values)
4
Expansion I/O1 fixed assignment
time: Input port start No. (I/O2)
-1 – 599
-1
-1
032 0 + (multiples of 8) (Invalid for negative values)
(Slot next to the standard I/O)
5
Expansion I/O1 fixed assignment
time: Output port start No. (I/O2)
-1 – 599
-1
-1
332 300 + (multiples of 8)
(Invalid for negative values)
6
Expansion I/O2 fixed assignment
time: Input port start No. (I/O3)
-1 – 599
-1
016 016 0 + (multiples of 8) (Invalid for negative values)
7
Expansion I/O2 fixed assignment
time: Output port start No. (I/O3)
-1 – 599
-1
316 316 300 + (multiples of 8)
(Invalid for negative values)
8
Expansion I/O3 fixed assignment
time: Input port start No. (I/O4)
-1 – 599
0
0
0
0 + (multiples of 8) (Invalid for negative values)
9
Expansion I/O3 fixed assignment
time: Output port start No. (I/O4)
-1 – 599
300 300 300 300 + (multiples of 8)
(Invalid for negative values)
10 Standard I/O error monitoring
(I/O1)
0 – 5
0
0
0
11 Expansion I/O1 error monitoring
(I/O2)
0 – 5
0
0
2
12 Expansion I/O2 error monitoring
(I/O3)
0 – 5
0
2
2
13 Expansion I/O3 error monitoring
(I/O4)
0 – 5
2
2
2
0: Non-monitoring
1: Monitoring
2: Monitoring (Non-monitoring of 24V I/O power
related errors)
(Main application of Ver. 0.55 or later)
3: Monitoring (Monitoring of 24V I/O power
related errors only)
(Main application of Ver. 0.55 or later)
14 Network I/F card remote: Number
of ports used for input
0 – 256
0
0
0
Multiples of 16
15 Network I/F card remote: Number
of ports used for output
0 – 256
0
0
0
Multiples of 16
(I/O1) to (I/O4) indicate the slot numbers.
Note: When a standard I/O board is not used, it is not required to supply 24V DC to the IO 24V power connector. In this
case, set the parameter No. 10 to “0.”