Factory-configured parameters (standard setting)
No. Parameter
name
Input
range
Set
value
Remarks
1
I/O port assignment type
0 – 20
1
0: Fixed assignment
1: Automatic assignment (Priority: slot 1
—
)
* The ports only in the continuous installation
range from slot 1 are assigned for safety.)
2 Standard
I/O:
Input port start No. (I/O1)
-1 – 599
000
0 + (multiples of 8) (Invalid for negative values)
3 Standard
I/O:
Output port start No. (I/O1)
-1 – 599
300
300 + (multiples of 8)
(Invalid for negative values)
4
Expansion I/O1 fixed assignment
time: Input port start No. (I/O2)
-1 – 599
-1
0 + (multiples of 8) (Invalid for negative values)
(Slot next to the standard I/O)
5
Expansion I/O1 fixed assignment
time: Output port start No. (I/O2)
-1 – 599
-1
300 + (multiples of 8)
(Invalid for negative values)
6
Expansion I/O2 fixed assignment
time: Input port start No. (I/O3)
-1 – 599
-1
0 + (multiples of 8) (Invalid for negative values)
7
Expansion I/O2 fixed assignment
time: Output port start No. (I/O3)
-1 – 599
-1
300 + (multiples of 8)
(Invalid for negative values)
8
Expansion I/O3 fixed assignment
time: Input port start No. (I/O4)
-1 – 599
-1
0 + (multiples of 8) (Invalid for negative values)
9
Expansion I/O3 fixed assignment
time: Output port start No. (I/O4)
-1 – 599
-1
300 + (multiples of 8)
(Invalid for negative values)
10 Standard I/O error monitoring
(I/O1)
0 – 5
2
11 Expansion I/O1 error monitoring
(I/O2)
0 – 5
0
12 Expansion I/O2 error monitoring
(I/O3)
0 – 5
0
13 Expansion I/O3 error monitoring
(I/O4)
0 – 5
0
0: Non-monitoring
1: Monitoring
2: Monitoring (Non-monitoring of 24V I/O power
related errors)
(Main application of Ver. 0.55 or later)
3: Monitoring (Monitoring of 24V I/O power
related errors only)
(Main application of Ver. 0.55 or later)
14 Network I/F card remote:
Number of ports used for input
0 – 256
64
Multiples of 16
15 Network I/F card remote:
Number of ports used for output
0 – 256
64
Multiples of 16
(I/O1) to (I/O4) indicate the slot numbers.