22
—
GO-5100M-USB / GO-5100C-USB
■
To save user settings
1
Stop image acquisition.
2
Expand [User Set Control], and select the save destination ([User Set1] to [User Set3]) in
[User Set Selector].
Note
The factory default setting values are stored in [Default] and cannot be overwritten.
Caution
Settings can only be saved when image acquisition on the camera is stopped.
3
Select [User Set Save], and click [Execute ‘User Set Save’ Command].
The current setting values are saved as user settings.
■
To load user settings
1
Stop image acquisition.
User settings can only be loaded when image capture on the camera is stopped.
2
Select the settings to load (User Set1 to User Set3) in [User Set Selector].
3
Select [User Set Load], and click [Execute ‘User Set Load’ Command].
The selected user settings are loaded.