53
—
GO-5100M-USB / GO-5100C-USB
Item
Setting range
Default value
Description
Pulse Generator Length
1 to 1048575
30000
Set the maximum count up value using
clock value.
Pulse Generator Length
(ms)
0.00222222 to 2330.17
66.6667
Set the maximum count up value using
ms.
This value is calculated based on the
Pulse Generator Length value.
The setting range varies depending on
the Clock Pre-Scaler value.
Pulse Generator Frequency
(Hz)
0.429154 to 450000
15
Set the maximum count up value using
frequency.
This value is calculated based on the
Pulse Generator Length value.
Pulse Generator Start Point 0 to 1048574
0
Set the start point for the High interval
using clock value.
When the counter reaches this value, the
output becomes 1.
Pulse Generator Start Point
(ms)
0 to 2330.164444
0
Set the start point for the High interval
using ms.
When the counter reaches this value, the
output becomes 1.
The setting range varies depending on
the Clock Pre-Scaler value.
Pulse Generator End Point
1 to 1048575
15000
Set the start point for the Low interval
using clock value.
When the counter reaches this value, the
output becomes 0.
Pulse Generator End Point
(ms)
0.002222 to 2330.166666
33.3333
Set the start point for the Low interval
using ms.
When the counter reaches this value, the
output becomes 0.
The setting range varies depending on
the Clock Pre-Scaler value.
Pulse Generator Pulse-
Width (ms)
0.002222 to 2330.166666
33.3333
Display High interval width for the pulse in
ms.
This is a calculation of the time between
the Start Point and End Point.
The setting range varies depending on
the Clock Pre-Scaler value.
Pulse Generator Repeat
Count
0 to 255
0
Set the repeat count for the counter.
When this is set to 0, the counter will be
free-running with limitless repeating.
Pulse Generator Clear
Activation
Off,
High Level,
Low Level,
Rising Edge,
Falling Edge
0: Off
Set the clear signal condition for the
count clear input of the pulse generator.
Pulse Generator Clear
Source
Low,
High,
Acquisition Trigger Wait,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
LVAL,
User Output 0,
User Output 1,
Line5 - Opt In 1,
Nand0 Out,
Nand1 Out
0: Low
Select the count clear input signal source.
Line4 TTL In is available on Standard
Model.
Pulse Generator Clear
Inverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
Pulse Generator Clear
Sync Mode
Async Mode,
Sync Mode
Async Mode
Select the sync mode for the count clear
input signal.
m) JAI Custom Control ALC
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
ALC Reference
10 to 95
50
Set the target level for ALC. (unit: %)