51
—
GO-5100M-USB / GO-5100C-USB
Item
Setting range
Default value
Description
g) Counter And Timer Control
Configure counter settings. (This camera
only supports counter functions.)
Counter 0 to 2
Counter 0 to 2
—
Display the counter.
Counter 0 to 2 Event
Source
Off,
Frame Trigger,
Frame Start,
Exposure Start,
Exposure Transfer End
Off
Select the counter event signal for which
to read the count value.
Counter 0 to 2 Event
Activation
Rising Edge,
Falling Edge
—
Specify the timing at which to count.
Counter 0 to 2 Reset
—
—
Reset the counter.
Counter 0 to 2 Refresh
—
—
Update the count value.
Counter 0 to 2 Value
—
0
Display the count value.
Counter 0 to 2 Status
Counter Active
Counter Active
Display the counter status.
h) User Set Control
Configure user settings.
User Set Selector
Default,
User Set1 to User Set3
Default (factory
default values)
Select the user settings.
User Set Load
—
—
Load user settings.
User Set Save
—
—
Save the current setting values as user
settings.
i) Sequencer Control
Configure sequencer settings.
Sequencer Mode
On, Off
Off
Enable/disable [Sequencer Mode].
Sequencer Mode Select
Trigger Sequencer Mode,
Command Sequencer Mode
Trigger
Sequencer
Mode
Select the sequencer mode.
Sequencer Configuration Mode On, Off
On
Select [On] to change the settings within
the index.
Sequencer Set Selector
1 to 128
1
Select the [Trigger Sequencer] mode and
[Command Sequencer] mode index.
Sequencer Frame Number
1 to 255
1
Set the number of frames to display for
the selected Sequencer Index. (Enabled
only for Trigger Sequencer.)
Sequencer Set Next
1 to 128
1
Set the next index to be displayed for the
selected Sequencer Index. (Enabled only
for Trigger Sequencer.)
Sequencer Width
16 to 2464
2464
Set the width of the selected Sequencer
Index.
Sequencer Height
2 to 2056
❖
GO-5100M-USB: 1 to
2056
2056
Set the height of the selected Sequencer
Index.
Sequencer Offset X
0 to 2448
0
Set the horizontal offset value for the
selected Sequencer Index.
Sequencer Offset Y
0 to 2054
❖
GO-5100M-USB: 0 to
2055
0
Set the vertical offset value for the
selected Sequencer Index.
Sequencer Gain
100 to 1600
100
Set the gain for the selected Sequencer
Index.
Sequencer Gain Red
-4533 to 37876
0
Set the Red Gain for the selected
Sequencer Index.
Sequencer Gain Blue
-4533 to 37876
0
Set the Blue Gain for the selected
Sequencer Index.
Sequencer Exposure Time (µs)
8-bit: 7 to 7999920
10/12 bit: 8 to 7999900
6210
Set the exposure time for the selected
Sequencer Index.
Sequencer Black Level
-133 to 255
0
Set the black level for the selected
Sequencer Index.
Sequencer LUT Enable
True, False
False
Enable/disable the LUT setting for the
selected Sequencer Index.
Sequencer H Binning
(GO-5100M-PGE only)
1 to 2
1
Set the horizontal binning for the selected
Sequencer Index.
Sequencer V Binning
(GO-5100M-PGE only)
1 to 2
1
Set the vertical binning for the selected
Sequencer Index.
Sequencer Repetition
1 to 255
1
Set the repeat count for the sequencer.
Sequencer LUT Mode
Gamma, LUT
Gamma
Set the sequencer LUT mode.
Sequencer Set Active
—
1
Displays the active LUT number.