6
7.
Mount the motor switch at this point. Install the switch to the front beam using
two #10-32 screws (Item E) and #10-32 nuts (Item F) and #10 flat washers (item G).
8.
Raise the leg assemblies to their highest point by using the motor control switch . Secure
the motorize pump hydraulic lines to underside of worksurface using cable mounts (items
M), cable ties (items N) and #6x.500 Phillips Screws (items L)
being sure not to kink or
damage the lines in anyway.
9.
Lower the bench slowly making sure to see that the pump hydraulic lines will not hang up on
anything. At this point raise and lower the bench to verify it is operating correctly.
10.
When moving bench into it place be sure to lift it by the bottom base part of the leg
assemblies only. DO NOT lift it by the worksurface or the top part of the frame as this can
cause damage to the hydraulic system.