New R-Line Refuse Collection Micro
User Manual RCM10
63
4.14.1 Troubleshooting
Fault
Remedy
Compacting shovel
The carriage arrives at its
lowermost limit, but the shovel
does not close and remains
pressurised
Check to see if the INPUT 37 is 1 in the display of cabin
Check the functionality or calibration of pressure switch SP2 on the solenoid
valve unit
The carriage ascends to its
uppermost limit and is blocked
Check to see if the INPUT 11 is 1 in the display of cabin
If the system remains pressurised, verify the proper functionality of proximity
sensor S3 on the upper part of the hatch (shovel raised sensor)
If the system does not remain pressurised, check to make sure that the single
or automatic cycle selector on the external button panel is set to its single
cycle position
The shovel opens and closes
without the carriage descending
Check the carriage descent coil
The shovel does not start when
the shovel activation switch is
engaged
Check to see if the INPUT 7 is 1 in the display of cabin
Check to make sure that the rear inspection edge is closed
Check sensor S16 on the edge
Check to make sure that the hatch is closed and that the latches are
extended