S10
2nd control,
acceleration
time 2 setting
2nd control,
acceleration
pattem setting
Range is 0.1 to 999.9sec in units of 0.1sec,
1000 3000sec in units of 1 sec. Second
acceleration can be set by the [2CH] terminal
input or frequency transition setting
Range is 0.1 to 999.9sec in units of 0.1sec,
1000 3000sec in units of 1 sec. Second
acceleration can be set by the [2CH] terminal
input or frequency transition setting
10.00sec
S11
S14
2nd control,
deceleration
time 2 setting
2nd control,
deceleration
pattem setting
2nd control,
2-stage
Accel./decel.
transition
method setting
10.00sec
S15
Output frequency at which Acc1 switches to
Acc2, range is 0.0 to 400.0Hz in units of
0.01Hz
Output frequency at which Dcc1 switches to
Dcc2, range is 0.0 to 400.0Hz in units of
0.01Hz
Set a level between 20% to 120% for the rated
inverter current
setting range : 0.2*(inverter ratedcurrent)
1.2*(
)
inverter ratedcurrent
0.00Hz
0.00Hz
100.0%
S16
2nd control,
acceleration
transition
frequency setting
2nd control,
deceleration
transition
frequency
setting
2nd control,
electronic
thermal level
setting
S17
Set the characteristic curve of Acc 1 and
Acc2, three options.
0:linear,
1:S-curve,
2:U-curve
S12
S13
0
Set the characteristic curve of Dec 1 and
Dec2, three options.
0:linear,
1:S-curve,
2:U-curve
0
Func-
code
Name
Description
Defaults
Run-
time
Edit
Func-
code
Name
Description
Defaults
0 --terminal(2CH), 1 -- transition frequency
frequency
Acc1
Acc2
time
2CH
0
N100
INSTRUCTION MANUAL
plus