CM2
12
50
max
DC 27Vmax
Open collector output
Fa1/ FA2
11
Option
Code
Terminal
Symbol
Function Name
Input
State
Description
1
FA1
Frequency arrival
type 1 signal
Frequency arrival
type 2 signal
ON
OFF
when output to motor is at the
set frequency
Valid for inputs:
Required setting
C13, C14, C21, C22
(none)
Notes:
At the time of acceleration, an arrival signal at
a frequency between the set frequency -0.5Hz
to +1.5Hz is turned on.
At the time of deceleration, an arrival signal at
a frequency between the set fre0.5Hz
to -1.5Hz is turned on.
The delay time of the output signal is 60ms
(nominal).
Example:
when output to motor is off,
or in any acceleration or
deceleration ramp
2
FA2
ON
OFF
when output to motor is at or
above the set frequency the
holds for, even if in acceleration
or deceleration ramps
when output to motor is off,
or during acceleration or decel-
eration before the respective
thresholds are crossed
RY
N100
INSTRUCTION MANUAL
plus