RY
CM2 12
11
Terminal
symbol
Description
Frequency
arrival
signal
Run signal
Overload
advance
notice signal
PID control error
deviation signal
Alarm signal
Common
terminal
Alarm
terminals
Frequency arrival [FA1][FA2] signals is indicated
when the output frequency accelerates and
decelerates to arrive at a constant frequency.
When the [RUN] signal is selected, the inverter
outputs a signal on that terminal when it is in
the RUN mode.
When the output current exceeds a preset value,
the [OL] terminal signal turns on.
When the PID loop error magnitude the
preset value, the [OD] terminal signal
turns on.
The inverter alarm signal is active when a fault
has occurred.
Common terminal for intelligent output terminal
At normal status, power off(initial setting value)
: Al0 - AL1(closed)
At abnormal status
: AL0 - AL2(closed)
Contact rating : 250V AC 2.5A(resistor 1oad) 0.2A(inductor load)
30V DC 3.0A(resistor 1oad) 0.7A(inductor load)
(minimum 100V AC 10mA, 5V DC 100mA)
FA1
(1)
FA2
(2)
RUN
(0)
OL
(3)
OD
(4)
AL
(5)
Intelligent
output
terminal
(1
1,
12)
CM 2
AL 0
AL 1
AL 2
Output terminal
specification
open-collector
output
27V DC max
50
max
FA1
FA2
Frequency
F01 set value
Time
ON at
constant
frequency
Frequency
Thresholds
Time
C22
C21
ON at target
frequency
Terminal name
N100
INSTRUCTION MANUAL
plus