User Manual
Installation
21
The devices should be installed far away from electromagnetic interferences such as large electric
devices.
Outdoor Installation and Maintenance
If the devices are installed outdoor, do not perform maintenance on extreme weathers such as storm,
extreme temperature or high humidity.
Grounding Requirements
The ground wire must be connected before device installation, and be removed after the device is
dismantled. Do not damage the grounding conductors.
Do not operate the devices when the grounding conductor is not installed.
The devices must be permanently grounded. Before any operation, please check the electrical
connection of the devices, making sure they are grounded properly.
4.3.2
Instruments and Tools
The following table lists the required tools:
Regular Tools
Torx screwdriver, Philips driver, flat blade screwdriver, adjustable wrench, Allen
wrench, cross-type torque screwdriver, combination wrench, rubber hammer,
and torque wrench.
Safety Tools
Antistatic wrist strap, safety belt, helmet, safety rope, and slip-proof gloves.
Cable Making Tools
Wire stripper, wire crimper, and wire cutter.
Measuring Tools
Multi-meter, tape measure, and level.
Auxiliary Tools
Fixed pulley, step ladder, marker pen, percussion drill, electrical tape, anti-UV
cable tie, label, screw kit, expansion screw, utility knife, heat gun, and duct tape.
4.3.3
Material Preparation
Before installation, check that all materials are well received according to the packing list.
4.4
Installing the Units
Place and fix the cable-access donor unit inside the cabinet.
The wireless-access donor unit and the remote unit can be mounted on a pole or wall as per needs. Check
latter chapters for more details.
Summary of Contents for DS-9300