background image

Installation & Control Guide for 

Low Surface Temperature Convector Panel Heaters 

with Electronic 7-Day Timer

 

All electrical appliances produced by the Company are guaranteed for one year against 
faulty  materials  or  workmanship.    This  applies  only  if  the  appliance  has  been  used  for 
purposes in accordance with the instructions provided and has not been connected to an 
unsuitable electricity supply, or subject to misuse, neglect, damage or modified or repaired 
by any person not authorised by us. This guarantee is offered to you as an extra benefit and 
does not affect your legal rights. 
 
The  correct  electricity  supply  voltage  is  shown  on  the  rating  label  attached  to  the 
appliance. 
 
Reasonable  care  has  been  taken  to  ensure  that  this  guide  is  accurate  at  the  time  of 
printing. In the interest of progress the Company reserve the right to vary specifications from 
time to time without notice.

 

Q

UALITY

 S

PACE

 H

EATERS

 

Models 

 

 

 

            

 

        

LST500ERF, LST800ERF

 

66001078 Iss 02 

Summary of Contents for LST500ERF

Page 1: ...ble electricity supply or subject to misuse neglect damage or modified or repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached to the appliance Reasonable care has been taken to ensure that this guide is accurate at the time of printing In t...

Page 2: ...to fixed wiring installation Note When switched on for the first time the appliance may emit a slight smell This is purely the evaporation of a fluid used in the manufacturing process WARNING This appliance must be earthed Thermally Operated Cut Out The appliance is fitted with a thermally operated cut out TOC This is a safety device which switches the heater off if for any reason the appliance ov...

Page 3: ...Installation 3 MILLIMETRES WATTS A B C D E LSTE500E 500 830 430 616 107 LSTE800E 800 1183 430 952 115 3 66001078 Iss 02 ...

Page 4: ...he display by pressing any button Press TEMP then use TEMP and MODE to change the temperature Once the temperature is set leave the display to return to the main screen and the settings will be saved 4 BOOST 15 minutes The boost feature increases the room temperature for 15 minutes 1 Use TEMP and MODE to set the temperature To amend the set temperature when in Boost mode simply activate the displa...

Page 5: ... and MODE to change minutes press PROG to set the minutes 7 The hour will be flashing 8 To set hour use TEMP and MODE to change hour press PROG to set the hour 9 The temperature will be flashing 10 To set temperature use TEMP and MODE to change temperature press PROG to set temperature To add another programme repeat steps 2 10 The LSTE has a 7 day timer with up to 6 programming steps available fo...

Page 6: ...en the settings 01 temperature calibration The temperature reading has been factory calibrated but if for any reason it needs adjusting better accuracy required to suit different position in the room etc the reading can be recalibrated in 0 5 degrees steps 02 change between degrees Celsius or Fahrenheit 03 set minimum temperature 3 5 deg frost protection When this is set the heater will operate in...

Page 7: ...r Check that the thermal cut out has not operated Follow the reset instructions given under the section headed Thermal Operated Cut out Check that the fuse in the spur unit has not blown This can be done by replacing the fuse with another suitable fuse Should none of the above remedies work then telephone the helpline number shown in these instructions UK ONLY Do not attempt to repair the heater 7...

Reviews: