Table 4: Installer Menu
Table 4: Installer Menu
Installer Menu
Setting Options
Menu Tasks & Explanations
SDC Wire
Connections
OT 0
Set Operator Type
0 = operator type
12 = SwingSmart DC 20 & DCS 20
Solar
14 = StrongArmPark DC 10 & DC14
DCS 10 Solar & DCS 14 Solar
15 = SlideSmart DC 15 &
DCS 15 Solar
16 = SlideSmart DC 10F &
DCS 10F Solar
Select the appropriate number for the
operator.
NOTE:
This menu item only appears if the
Smart DC Controller is being replaced.
CAUTION: If you are replacing an SDC
board, remember to transfer the operator’s
menu settings from the existing board
to the replacement board. Refer to the
installation instructions that accompany the
replacement SDC board.
Not applicable
(N/A)
MN 0
Model Number
0 = model type unknown
1 = Model 10
2 = Model 14
Select the type of StrongArmPark DC model
used at the site.
NOTE:
This menu item only
appears when you set the OT (operator type).
N/A
LL 0 (OFF)
Learn Limit Reset
0 = Normal setting
1 = Erases learned limit positions
Set to option 1, the system resets to
accommodate for relearning limits.
N/A
UC 0
Usage Class
0 = gate disabled
1 = Family dwelling (1 to 4 units)
2 = Multi-family & commercial
3 = Light industrial*
4 = Industrial/guarded secure*
*Not serving the general public
Set the UL usage class. The installer must set
the usage class for the operator to function.
See
Identifying Gate Operator Category and
Usage Class on page 7
.
NOTE:
The usage class setting does not
appear on StrongArmPark DC and Crash
products.
N/A
SH 0
Gate Handing
0 = gate disabled
R = viewed from the secure side, the
arm lifts right to open
L = viewed from the secure side, the
arm lifts left to open
The handing determines which way the gate
opens as you view it from the front access
panel.
NOTE:
StrongArmPark DC is factory
configured for left handing.
N/A
OS 1
Open Speed
DC10 DC14
1 = 2.5 seconds 1 = 3.5 seconds
2 = 2.0 seconds
2 = 3.0 seconds
3 = 1.5 seconds
3 = 2.5 seconds
Adjust how quickly the barrier arm opens.
CS 1
Close Speed
1 = 2.5 seconds 1 = 3.5 seconds
2 = 2.0 seconds
2 = 3.0 seconds
3 = 1.5 seconds
3 = 2.5 seconds
Adjust how quickly the barrier arm closes.
FD 0 (OFF)
Load Factory Defaults
0 = user settings
1 = reload factory settings
Select setting 1 to return the operator to
factory defaults which globally restores all
menu settings back to new operator status.
NOTICE:
If factory defaults are restored,
any customized menu settings will need to
be reprogrammed. Before loading factory
defaults, you can save your customized menu
settings using a PC laptop & S.T.A.R.T.
N/A
DG 0 (OFF)
Dual Gate
0 = solo operator
1 = Slave unit
2 = Master unit
3 = Sally Port A
4 = Sally Port B
Establishes communication after wiring dual
gate connections between two operators
in Master/Second (Slave) or Sally Port site
configurations.
This menu item appears if the sequenced gate
menu item SG is set at 0 (off).
Dual Gate COM
(Gate 1) to Dual
Gate COM (Gate 2)
A to A
B to B
www.hysecurity.com
© 2017