DELAYED EGRESS DEVICE

Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display

Features:

Egress Delay

 

15 or 30 second exit delay

 

1 or 2 second nuisance delay

Built-In 3 Function keypad

 

Alarm and lock reset

 

1 to 30 second bypass

 

Sustained bypass

 

Additional key switch optional

Control Inputs

 

1 to 30 second request-to-exit and 
bypass  input with anti-tailgate and 
jumper selectable door prop alarm.

 

Reset

Built-In Annunciation

 

Armed mode

 

Nuisance mode

 

Irreversible egress mode

 

Release mode

 

Digital countdown mode

 

Field selectable voice notification or tone

 

Field selectable male voice with security 
message or female voice with safety 
message

Trigger Modes

 

Egress alarm triggered by Push Bar

 

Trigger input from external device 
field selectable (N/O or N/C)

Code Compliance

 

IFC International Fire Code

 

IBC International Building Code

 

NFPA 101 Life Safety Code

 

NFPA 1 Uniform Fire Code

 

California Building Code

 

Field selectable automatic or manual 
power up after emergency release or 
power loss.  Use of manual power up 
complies with California Building Code 
(OSHPD) requirements.

P:\INST INSTRUCTIONS\Delayed Egress\INST-6000\INST-S6000DE_KDE       Rev D       11-20       Page 1

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

Choice of Mounting

 

Recessed mounted

       (3 gang metal plaster ring included)

 

Surface mounted with optional 3 gang 
box (DEC-J)

 

Optional shroud (SHD-J) to be used with 
DEC-J surface box.

Rim Mount, Surface Vertical Rod, or Mortise Exit Device

NOTE: SDC 600 Series Power Supply required

Application:

When unauthorized egress is initiated SDC Exit Check

®

  delays egress through the door for 15 seconds (or 30 seconds).  Meanwhile, 

the person exiting must wait while personnel or security responds.  The exit device unlocks after 15 seconds have elapsed, permitting 
egress. When powered by a fire control supervised power supply, the exit device will allow egress immediately in an emergency.

The integral verbal message, digital countdown display and sign provide comprehensive and clear instructions of the door operation for 
persons without prior knowledge of the exit delay, including the sight and hearing impaired.

The digital keypad eliminates the need to carry and locate keys for reset and bypass functions.

Monitoring Outputs

 

Egress initiation status

 

Secure/unsecure status

S6000DE

MODELS

S6000KDE

Exit Check

®

 Applications include:

 

Restricting the egress of wandering patients 
for their own safety.

 

HUGS

®

 Infant Protection System 

compatibility

 

Restricting the egress of commercial center 
patrons for security application needs.

 

Controlling pedestrian traffic in 
transportation facilities, including airport 
jetways and tarmacs

 

Reducing  Shoplifting and Employee Theft 

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

INSTALLATION INSTRUCTIONS

Summary of Contents for S6000DE

Page 1: ...aster ring included Surface mounted with optional 3 gang box DEC J Optional shroud SHD J to be used with DEC J surface box Rim Mount Surface Vertical Rod or Mortise Exit Device NOTE SDC 600 Series Power Supply required Application When unauthorized egress is initiated SDC Exit Check delays egress through the door for 15 seconds or 30 seconds Meanwhile the person exiting must wait while personnel o...

Page 2: ...r Unlocking the door for extended periods of time Authorized Bypass mode is accomplished by entering an Authorized Bypass code on the integral keypad turning the optional key switch to the Bypass position or placing a maintained closure across REX terminals Releasing the closure across the REX terminals will initiate the Request to Exit cycle Entering the Reset code on the integral digital keypad ...

Page 3: ...O LOCK CYLINDER IN PLACE 1 1 8 KEY CYLINDER 7185SC1 26D KD 1 1 4 KEY CYLINDER REQUIRES COLLAR 3 3 4 1 Cut hole in dry wall to dimensions shown 2 Mount wall bracket over hole 3 Carefully insert unit and secure with screws supplied 5 3 4 PTH 4 Power Supply SDC 600 Series PTH 4 Power Transfer Hinge PTH 4DPS Power Transfer Hinge w DPS MC 4 Recessed DPS SDC P N Power Supply SDC 600 Series PTH 4 8 Wires...

Page 4: ... MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES VIEW A A WIRE UNIT AS SHOWN SHOWN WITH NO OPTIONS REX TRIG RESET IBO J4 J6 J1 KEYPAD RESET C NO C NO C NO C NO C NC NO C NC NO PWR LOCK RED RLY GRN RLY SP1 TO PANIC DEVICE FROM POWER SUPPLY TO DPS SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box...

Page 5: ...d open past the request to exit period No alarm will sound J6 24VDC 430mA Single 680mA Tandem Monitor Relays Contact Rating Operating Temp Range Power Requirements SPDT Dry 1 Amp 12 24VDC Resistive 0 C to 70 C Door Contact OR Power Transfer Hinge by DPS required for Anti Tailgate BOCA Door Prop or Forced Door operation C N C N O GRY YEL 101 DE 101 KDE PWR LOCK RED R NO C TRIG REX RESET C NO C NO C...

Page 6: ...hes 00 the door will unlock 15 14 01 DELAYED EGRESS MODE 00 00 The door is unlocked and has been opened ALARMED UNLOCKED Alternating Display The door is unlocked and the alarm is sounding To return to Armed Mode close the door and turn the keyswitch to Reset or enter the Reset Code 11 on the keypad RESET Armed Keypad Code 11 Green LED solid The door is locked and secure 15 30 or The door is unlock...

Page 7: ...Relay For example 1 05 55 2 adds user 5 s pin code as one that will activate authorized exit Output Relay Codes 2 Reset 3 Authorized Exit 4 Bypass P INST INSTRUCTIONS Delayed Egress INST 6000 INST S6000DE_KDE Rev D 11 20 Page 7 Entering Programming Mode Press 99 Master Code For example 99 1234 Enters programming mode using the Default Master Code Changing the Master Code User 1 is always used as t...

Page 8: ... NO C NO GRN RLY NO C NC NO C NC IBO C NO Close to Override Bypass Close Hold to Unlock REX TRIG RESET IBO J4 J6 J1 KEYPAD RESET C NO C NO C NO C NO Jumper Removed IBO input used for Patient Monitoring WHT WHT BLK RED POWER TRANSFER HINGE x DPS SINGLE DOOR Alarm Secure Monitor Relays C GREEN N O RED N C WHT MC 4 NOTE All door switches are shown in an active state i e Door is closed C N C N O GRY Y...

Page 9: ... Template are shown in inches See attached page for the Metric Conversion Table for millimeters P INST INSTRUCTIONS Delayed Egress INST 6000 INST S6000DE_KDE Rev D 11 20 Page 9 SECURITY DOOR CONTROLS WWW SDCSECURITY COM t 800 413 8783 805 494 0622 E mail service sdcsecurity com 801 Avenida Acaso Camarillo CA 93012 PO Box 3670 Camarillo CA 93011 INSTALLATION INSTRUCTIONS ...

Page 10: ...mplate 3 Drill holes as marked on door and jamb or mullion INSIDE FACE OF DOOR JAMB C L OF STRIKE 40 to Finished Floor C L OF DEVICE 2 7 16 C L TRIM TRIM DOOR DOOR DOUBLE DOOR STRIKE Strike Chassis Cover Chassis Chassis Latch Assembly Push Bar End Cap End Cap Bracket Dogging Device Fire Exit Hardware is not Equipped with this device P INST INSTRUCTIONS Delayed Egress INST 6000 INST S6000DE_KDE Rev...

Page 11: ... break off points then fasten screws F INSTALL OUTSIDE TRIM Mark and drill holes for the outside trim see trim instructions E INSTALL DEVICE BODY 1 Remove chassis cover from latch assembly and end cap from end cap bracket 2 Place the device horizontally over the drilled holes and attach with the supplied mounting screws Bolt device chassis to trim with sexbolts if required 3 Make sure cylinder or ...

Page 12: ... below 2 Make sure and secure latch bolt engagement Adjust strike if required 3 Install chassis cover on chassis 4 Install end cap Note For increasing the life of this device dogging device during high traffic period of the day Panic device only Dogging Wrench Allen Key Dogging Depress push bar Insert dogging wrench and turn clockwise 35 degrees Depress push bar The push bar will remain depressed ...

Reviews: