Learn Open Limits
1.
Press and hold the OPEN button while the degrees increase
toward 90 and the barrier arm reaches the desired full open
position.
2.
Release the OPEN button as the arm nears full open. The motor
slows as do the numbered increments on the display. Note that if
you go too far, you can press CLOSE to reverse direction.
3.
Press STOP twice to preserve the open stop location. The buzzer
chirps twice and the full open stop is retained in memory.
Learn Close Limits
1.
Press and hold the CLOSE button while the degrees increase
toward - 90 and the barrier arm reaches the desired full open
position.
2.
Release the CLOSE button as the arm nears full open. The motor
slows as do the numbered increments on the display. Note that if
you go too far, you can press OPEN to reverse direction.
3.
Press STOP twice to preserve the open stop location. The buzzer chirps twice and the full open stop is
retained in memory.
t
est
tHe
o
perator
Complete the installation by testing the operation of the gate.
NOTE:
The operator must be turned on and in Run mode. A Run mode display appears on the SDC. If a Run mode status does not
appear on the display, press Reset. If an error, alert, or fault appears on the display, refer to the
Troubleshooting
section to learn
how to clear the display and return to Run mode.
1. Press Open to open the barrier arm.
2. Test the operator.
• Cycle the barrier arm a few times by pressing the Close and Open buttons.
NOTE:
If additional accessories are to be added, read about
SDC Inputs & Wiring on page 33
.
LEARN OPEN
DEGS: +XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LEARN CLOSE
DEGS: - XXX.X
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
www.hysecurity.com
© 2017
Display & Menu Options
MX3650-01 Rev. D
31