HyQuest Solutions Pty Ltd
Point Velocity Display - Model PVD100
©
Copyright
34
Issue 1.00 4 Apr, 2007
Specifications…
(continued)
Contact time to Fault Detection (
absolute maximum
)
(Normal Mode)
Magnetic Head Contact
11 Seconds
Cat
Whisker
Head
Contact
7
Seconds
(Slow speed Mode)
Magnetic Head Contact
30 Seconds
Cat
Whisker
Head
Contact
20
Seconds
Minimum dwell angle for
10
o
Cat Whisker Head
Signal Output driver pulse
Normal mode : 100mS, active high to low pulse
(FET open drain O/P)
Slow mode : 1 Sec, active high to low pulse
(Fixed width)
(1)
NOTES: a) Measurements and Computations based on the following Rating Table
Equations.
Price AA Meter: V=2.2048 +0.0178 where: V= Velocity
T
T
=
Seconds/rotation
Pygmy Meter: V=0.9604 +0.0312
T
b) Measurements made with 0 microSiemens conductivity, open air, ambient
room temperature.
User Serial Interface Program
Example: 2.3456[n]+0.1234 where: n=number of rotations/second
First Term:
2.3456
Second Term:
0.1234
First Term Entry:
Maximum Allowable: 6.5535
Second Term Entry:
Maximum Allowable: 0.9999
Range Values:
Maximum Allowable: 9.99
Note:
Incorrect or unreasonable entries can give unexpected results.