![HyQuest Solutions iRIS 270 User Manual Download Page 84](http://html1.mh-extra.com/html/hyquest-solutions/iris-270/iris-270_user-manual_2194079084.webp)
© 2022 HyQuest Solutions
84
Configuration
11. Create three objects and points with Object
TYPE: ANALOGUE OUTPUT
:
12. The points associated with these objects should have unique (with in the group) Identifier of 0, 1 and 2.
13. Create three objects and points with Object
Type: Analogue Input
:
14. The points associated with these objects should have unique (with in the group) Identifier of 0,1 and 2.
15. Configure the PLC to poll the iRIS with the following details:
Function:
Write Multiple Holding Registers
Slave Address:
0
Register address:
40201 or 200 (depends on PLC operation)
Number of registers
to write:
3
Register data type:
Signed 16-bit Integer
16. Configure the PLC to poll the iRIS with the following details:
Function:
Read Multiple Holding Registers
Slave Address:
0
Register address:
40204 or 203 (depends on PLC operation)
Number of registers
to retrieve:
3
Register data type:
Signed 16-bit Integer
The configuration is complete. To aid in understanding the data flow in this example the following table may act as a
visualisation. The Objects listed are those created above (the actual names will different in reality, for example Gate height
SP, etc.).