© 2022 HyQuest Solutions
67
Configuration
25. Next set up the Sensor 2 to log the internal battery voltage. Expand the sensors branch and click the +Add Sensor
option.
26. Click on the newly created “Disabled” sensor in the tree. Then repeat the steps used for configuring the Water Level
sensor earlier, but in this case, select Battery Voltage (External) and name it “Battery Voltage”. The configuration
should look like this:
27. Set up the logging parameters, with a simple 60 log rate.
28. In our example we are logging the averaged battery voltage every 60 minutes. We have set a low voltage alarm at
12.1 volts which resets when the battery rises to at least 12.5 volts again. The configuration tabs should look like this: