Installation
3
XPR300
Instruction Manual
809480
75
Shield water (VWI and OptiMix)
Shield water requirements (VWI and OptiMix)
on page 51. You must supply the shield water for your
cutting system.
Make sure that the water quality meets requirements.
Make sure that the water pressure meets requirements.
Make sure that the water flow meets requirements.
Make sure that the water plumbing and hoses meet requirements. Refer to
As an installer or user, you must supply the plumbing and hoses for shield water.
Make sure that the plumbing is the correct type and correctly installed.
Make sure that the hoses are the correct type and length, and that they are correctly installed.
Additional water pressure regulators are only required when the water pressure is above 7.92 bar
(115 psi). Refer to
Additional regulator requirement for shield water (optional)
Configuration
Requirements to position system components
Make sure that the configuration of system components is correct. Refer to
Configuration with VWI or OptiMix gas connect console
Make sure that the spacing and ventilation for the plasma power supply meets requirements. Refer to
Distance requirements for ventilation and access
Hypertherm recommends a minimum distance of 1 meter (3.3 feet) between the plasma power supply and
other system components, or between the plasma power supply and an obstacle.
Make sure that the surfaces that hold system components are flat, dry, clean, and can support the weight.
Refer to
Make sure that the table ventilation meets requirements (if applicable) (check table type).
Water table
Downdraft table
Other (specify)
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...