Diagnostics and Troubleshooting
8
XPR300
Instruction Manual
809480
327
Over temp diagnostic codes – Inductors (580 – 583), Transformers (586)
1.
Make sure that the clearance around the plasma power supply is adequate.
For adequate ventilation, Hypertherm recommends a minimum separation
distance of 1 meter (3.3 feet) between the plasma power supply and any
other objects or equipment.
Make sure that the ambient temperature where the plasma power
supply is located is within the acceptable temperature range for
cutting system operation. Refer to
If the
temperature where your plasma power supply is located is above the
temperature limit, you can experience reduced performance and
over-temp diagnostic codes.
2.
While all of the fans continue to operate, allow the cutting system to cool.
Before you continue with the next step, make sure that the magnetics
reach a temperature of 160ºC (320ºF) or below.
3.
Without removing the external side panel
on the plasma power supply, look through the
ventilation trusses on the plasma power supply to examine both magnetic fans inside.
Look through the ventilation trusses on the front of the plasma power
supply to locate the 2 magnetic (254 mm / 10 inch) fans inside. It is
not
necessary to remove the external panels to view the magnetics fans.
Magnetic fans are near the front and bottom.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before doing troubleshooting or diagnostic work.
All work requiring removal of the plasma power supply outer cover or panels
must be done by a qualified technician.
See the
Safety and Compliance Manual
(80669C) for more safety
information.
CAUTION
MOVING BLADES CAN CAUSE INJURY
Keep your hands away from moving parts.
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...