Diagnost
ics and
Tr
oubleshoo
ting
8
28
8
80
94
80
In
s
tru
c
tio
n
M
a
n
u
a
l
XPR
3
0
0
640
Info
No error
There are no active faults.
No operator action necessary.
None
—
642
Info
System powered
Power is supplied to the XPR
cutting system and the
customer-supplied, remote
on-off switch is in the ON
position (enabled).
None
Start or set
process;
remote on-off
643
Info
No process loaded Power is supplied to the XPR
cutting system and no
process is selected.
Select a process to end the Initial checks (2) State
of operation and start the Gas purge State (there is
no limit for how long the system waits for input).
Refer to
None
Start or set
process;
remote on-off
645
Info
System is off
Power is supplied to the
cutting system and the
customer-supplied, remote
on-off switch is in the OFF
position (disabled).
No operator action necessary. XPR cutting system
operation continues when the remote on-off switch
is set to the ON position. Refer to
None
Start or set
process;
remote on-off
646
Info
System turned off
Power is removed from the
XPR cutting system.
Shut down
Start or set
process;
remote on-off
647
Info
Process selected
Shows the operator-selected
process.
No operator action necessary.
None
Start or set
process;
remote on-off
654
Alert
CH1ArcOnTimeout During Ignite State, Chopper
1 does not enter Arc-On
State for at least 100
milliseconds.
1.
Remove the power from the cutting system.
2.
Restore electrical power to the cutting system.
3.
Send a process command to the cutting
system.
4.
If the code continues, contact your cutting
system supplier or regional Hypertherm
Technical Service team.
End of cycle
Remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description
Corrective action
XPR action
Code cancels
with
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...