Shield water requirements (VWI and OptiMix)
If you use water as a shield fluid, refer to
for water pressure and flow requirements and
If using shield water, the temperature range for cutting system operation
and storage is reduced to above 0°C to 40°C (32°F to 104°F).
Table 9
– Quality, pressure, and flow requirements for shield water
Table 10
– Purity requirements for shield water
A TDS meter indicates the Total Dissolved Solids (TDS) of a solution.
Dissolved ionized solids (such as salts and minerals) increase the
electrical conductivity of a solution. Total dissolved solids can be tested
with a TDS meter (Hypertherm Waterjet part number 1-13897) available
from Hypertherm.
* Water that does not meet minimum purity specifications can cause excessive deposits on the torch nozzle
and shield. These deposits can alter the water flow and produce an unstable arc. Refer to
requirements (VWI and OptiMix)
Quality*
Minimum and
maximum pressure
Flow rate required
Deionized water is
not
recommended to use as shield water.
Deionized water will react with the copper components in the
system and result in decreased life of components and
consumables.
Hypertherm recommends that you contact a water-quality
expert for guidance.
2.76 bar (40 psi)
minimum
8.27 bar (120 psi)
maximum
35 L/h (9.4 US gal/h)
Particulate type
Purity requirement
Total dissolved solids
< 61 PPM
C magnesium
< 40 PPM
Silica
< 5 PPM
pH
6.5 – 8.0
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...