Installation
3
74
809480
Instruction Manual
XPR300
Installation checklist
System requirements
Electrical
System electrical requirements
Make sure that the electrical system conforms to all applicable codes.
Make sure that the input power meets requirements. Refer to
Make sure that the circuit breaker or fuse meets requirements. Refer to
Make sure that the main power cord is the correct size and correctly installed. Refer to
As an installer or user, you must supply the main power cord for your cutting system.
Make sure that there is a separate line-disconnect switch for the plasma power supply. Refer to
Line-disconnect switch requirements
As an installer or user, you must supply the line-disconnect switch for your cutting system.
Make sure that the emergency-stop switches are correctly installed.
As an installer or user, you must supply the emergency-stop switches for your cutting system.
Make sure that the remote on-off switch is correctly installed. Refer to
As an installer or user, you must supply the remote on-off switch for your cutting system.
Process gas and plumbing
Process gas requirements (Core, VWI, and OptiMix gas connect consoles)
on page 46. You must supply
the process gases and supply gas plumbing for your cutting system.
Make sure that the gas quality meets requirements.
Make sure that the gas pressure meets requirements.
Make sure that the gas flow meets requirements.
Make sure that the gas plumbing and hoses meet requirements. Refer to
The cutting system comes with the hoses that connect the plasma power supply components.
As an installer or user, you must supply the plumbing for the process gases.
Make sure that the plumbing is the correct type and correctly installed.
As an installer or user, you must supply flashback arrestors for your cutting system if you use
oxygen as the plasma gas.
Make sure that the hoses are the correct type and length, and that they are correctly installed.
Make sure that the regulators are the correct type, installed in the correct locations, and correctly
installed. Refer to
As an installer or user, you must supply the gas regulators for your cutting system.
Make sure that the plumbing conforms to all applicable codes.
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...