Diagnost
ics and
Tr
oubleshoo
ting
8
30
0
80
94
80
In
s
tru
c
tio
n
M
a
n
u
a
l
XPR
3
0
0
739
Alert
Solenoid error V10
There is an over-current
condition for valve V10 at the
PCB in the torch connect
console.
1.
Examine the wiring for the valve.
2.
Connect the valve wire to another valve. If the
error goes away, the valve is bad.
3.
Replace the bad valve.
4.
If the code continues, examine the leads. Make
sure the continuity in the leads is good.
5.
If the continuity is good and the code continues,
replace the control PCB in the torch connect
console.
Ramp down
Set process;
remote on-off
740
Alert
Solenoid error V11 There is an over-current
condition for valve V11 at the
PCB in the torch connect
console.
Ramp down
Set process;
remote on-off
741
Alert
Solenoid error V12 There is an over-current
condition for valve V12 at the
PCB in the torch connect
console.
Ramp down
Set process;
remote on-off
742
Alert
Mix I2C1 Alert
There is a mixing alert for
I2C1.
1.
Examine the cable used to ground the gas
connect console. Connect any disconnected
cable or repair a damaged cable if found.
2.
Make sure that all external panels for all system
components are correctly installed. Install loose
or missing panels if found.
3.
Make sure that all hardware that holds the
external panels is in position and is tight.
None
Set process;
remote on-off
743
Alert
Mix I2C2 Alert
There is a mixing alert for
I2C2.
None
Set process;
remote on-off
744
Alert
Low Speed-
MagFan 1
The fan tachometer feedback
is below the minimum.
1.
Examine the fan. Make sure that the following
fan connections are good and tighten loose
connections if found:
• The fan connector
• The wiring to J2 and J5 on the fan power
distribution PCB
• The wiring to J7 on the control PCB 1
2.
Examine the 48 VDC power source output. If
not correct, replace the 48 VDC power source.
3.
If you do not find any loose connections and the
48 VDC power source is good, replace the fan.
None
Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description
Corrective action
XPR action
Code cancels
with
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...