Diagnostics and Troubleshooting
8
XPR300
Instruction Manual
809480
317
Low shield water pressure code (532)
1.
Make sure that the shield water pressure supplied to the cutting system is between 2.76 bar –
7.93 bar (40 psi – 115 psi).
If the pressure is less than 2.76 bar (40 psi), then a “booster” water pump
can be necessary to avoid system shut down or bad cut quality. Refer to
Shield water requirements (VWI and OptiMix)
2.
Examine all water hoses and water hose inlet fittings. Look for:
Damage or kinks that can restrict flow.
Leaks that can decrease pressure.
3.
Replace any hoses with damage or kinks.
4.
Reposition the hoses if you find fixable kinks.
5.
Replace any fitting that has damage.
6.
Tighten loose connections if found.
7.
Examine water regulators. Look for debris that can block the flow path.
8.
Adjust the inlet water pressures to at least 2.77 bar (40 psi) when cutting, if necessary.
The Hypertherm-supplied regulator that is connected to the gas connect
console is pre-set at the factory. Do
not
adjust this regulator.
9.
If you cannot find or fix the problem with these corrective actions, contact your cutting machine
supplier or regional Hypertherm Technical Service team.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before doing troubleshooting or diagnostic work.
All work requiring removal of the plasma power supply outer cover or panels
must be done by a qualified technician.
See the
Safety and Compliance Manual
(80669C) for more safety
information.
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...