Alert
This code occurs
only with cutting
systems that have
firmware at Rev J
or earlier
Hv relay fault
The high-voltage relay driver
detects an over current
condition.
1.
Remove the power for the XPR cutting system.
2.
Remove the top and side panels from the torch
connect console.
3.
Examine the ohmic PCB inside the torch
connect console.
4.
Remove J2 from the ohmic PCB.
5.
Use an ohmmeter and needle probes to
measure the coil resistance across the 2
sockets (J2, 2 female connector). You can
expect a resistance of approximately 126 ohms.
6.
If the ohms value is more than 10% above or
below 126 ohms, replace the ohmic relay
(Hv relay).
7.
If the ohms value is within acceptable range,
make sure that you have the most recent XPR
firmware. Log into the Xnet at
www.hypertherm.com
to download it.
None
Set process;
remote on-off
779
Alert
Ch1 15V bus
The Chopper 1 15 V bus is
out of range (below 13 V or
above 17 V).
1.
Examine the 24 VDC on the connector J2,
pins 1 and 2 on the Chopper 1 assembly.
2.
If the 24 VDC is absent, examine the wiring on
J2 of Chopper 1. Look for loose connections.
3.
If you measure 24 VDC, replace the Chopper 1
assembly.
None
Set process;
remote on-off
780
Alert
Ch2 15V bus
The Chopper 2 15 V bus is
out of range (below 13 V or
above 17 V).
1.
Examine the 24 VDC on the connector J2, pins
1 and 2 on the Chopper 1 assembly.
2.
If the 24 VDC is absent, examine the wiring on
J2 of Chopper 2. Look for loose connections.
3.
If you measure 24 VDC, replace the Chopper 2
assembly.
None
Start or set
process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description
Corrective action
XPR action
Code cancels
with
Summary of Contents for XPR170
Page 1: ...XPR300 Instruction Manual 809480 REVISION 6 ENGLISH ...
Page 8: ......
Page 38: ...Specifications 1 38 809480 Instruction Manual XPR300 ...
Page 72: ...Qualifications and Requirements 2 72 809480 Instruction Manual XPR300 ...
Page 146: ...Installation 3 146 809480 Instruction Manual XPR300 ...
Page 202: ...Coolant Installation 5 202 809480 Instruction Manual XPR300 ...
Page 236: ...Operation 6 236 809480 Instruction Manual XPR300 ...
Page 360: ...Diagnostics and Troubleshooting 8 360 809480 Instruction Manual XPR300 ...
Page 406: ...Parts List 9 406 809480 Instruction Manual XPR300 ...
Page 417: ...417 Overview Sheet 1 of 22 013403 013403 ...
Page 418: ...418 Plasma power supply 1 Sheet 2 of 22 013403 ...
Page 419: ...419 Plasma power supply 2 Sheet 3 of 22 013403 ...
Page 420: ...420 Plasma power supply 3 Sheet 4 of 22 013403 ...
Page 421: ...421 Plasma power supply 4 Sheet 5 of 22 013403 ...
Page 422: ...422 Plasma power supply 5 Sheet 6 of 22 013403 ...
Page 423: ...423 Plasma power supply 6 Sheet 7 of 22 013403 ...
Page 424: ...424 Plasma power supply 7 Sheet 8 of 22 013403 ...
Page 425: ...425 Gas connect console 1 Sheet 9 of 22 013403 ...
Page 426: ...426 Gas connect console 2 Sheet 10 of 22 013403 ...
Page 427: ...427 Torch connect console Sheet 11 of 22 013403 ...
Page 428: ...428 Coolant system Sheet 12 of 22 013408 ...
Page 429: ...429 Gas system 1 Sheet 13 of 22 013403 ...
Page 430: ...430 Gas system 2 Sheet 14 of 22 013403 ...
Page 431: ...431 Gas system 3 Sheet 15 of 22 013403 ...
Page 438: ...438 Wireless subsystem block diagram Sheet 22 of 22 013403 ...