Controller
‐
Monitoring
34
Figure
16:
Monitoring,
Process
Fluid
Circuit
Dis
Press:
Measured
supply
pressure
of
cold
water
circuit
from
chiller.
Flow
Rate:
Total
process
pump
flow
rate
=
Plasma
system
flow
rate
+
bypass
flow
rate.
Tank
Level:
Measured
coolant
reservoir
level.
Figure
17:
Monitoring,
Recirculation
Circuit
Flow
Rate:
Measured
Inlet
Fluid
flow
rate.
Tank
Temp:
Measured
fluid
temperature
in
tank.
Tank
Level:
Measured
coolant
reservoir
level.
Figure
18:
Monitoring,
Filter
Status
In
Press:
Inlet
pressure
to
the
Fluid
filter
on
the
facility
fluid
circuit.
Out
Press:
Outlet
pressure
form
the
fluid
filter
on
the
facility
fluid
circuit.
Delta
Press:
Difference
between
the
Fluid
pressure
on
the
inlet
and
outlet
of
the
Fluid
filter
on
the
facility
fluid
loop.
Max
Delta:
Maximum
delta
pressure
threshold
allowed
between
the
inlet
and
outlet
of
the
fluid
filter
on
the
facility
fluid
loop.
Flow
Rate:
Measured
cold
water
circuit
supply
flow
rate
through
the
filter.
Hypertherm, Inc. Part Number: 810540
Summary of Contents for Koolant Koolers N-Series
Page 61: ...Appendix B Electrical Schematics PLC 59 PLC Hypertherm Inc Part Number 810540...
Page 62: ...Appendix B Electrical Schematics I O Module 60 I O Module Hypertherm Inc Part Number 810540...
Page 63: ...Appendix B Electrical Schematics Logic 61 Logic Hypertherm Inc Part Number 810540...
Page 73: ...Appendix E Declaration of Conformity 71 Hypertherm Inc Part Number 810540...
Page 74: ...Appendix E Declaration of Conformity 72 Hypertherm Inc Part Number 810540...
Page 75: ...Appendix E Declaration of Conformity 73 Hypertherm Inc Part Number 810540...