5 – Preventive maintenance
Preventi
ve maintenance
4.
Pour the water out of the filter housings.
5.
Remove the used filter cartridges from the filter housings.
6.
Put a new 0.45-micron filter cartridge in the housing with the plug at the bottom and the gray rubber gasket
at the top.
7.
Put a new filter cartridge in the 1-micron filter housing and the 10-micron filter housing.
The 1-micron and the 10-micron filters do not have a designated top or bottom.
8.
Install the filters and the housings with the 10-micron water filter nearest to the water valve.
9.
Discard the used parts.
10.
Use a filter wrench to tighten each of the filter housings.
11.
Close the water valve.
12.
Turn ON the water to the pump.
13.
Turn ON the pump in cooling mode.
Water valve in the closed position
1
2
3
1
10-micron water filter
2
1-micron water filter
3
0.45-micron water filter
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...