5 – Preventive maintenance
Preventi
ve maintenance
Install the output adapter and the high-pressure poppet assembly
Required parts, tools, and materials
15563 HyPrecision premium high-pressure seal repair kit
15568 HyPrecision S- and D-series poppet repair kit
11530 Output adapter
High-pressure antiseize lubricant such as Blue Goop or AccuGoop
1-inch crowfoot wrench or socket
13/16-inch open-ended wrench or socket
Torque wrench
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a
high-pressure connection. Using only 1 wrench can increase bending stress to the parts and cause
damage or premature failure.
Service
Interval
Replace the high-pressure poppet assemblies
After every 1,000 hours of operation
Replace the output adapters
After every 6,000 hours of operation
1
2
3
4
1
High-pressure poppet seat
2
High-pressure poppet
3
High-pressure poppet spring
4
Output adapter
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...