32
HyPrecision 50S/60S/75S
Operator Manual
808690
2 – Product description
Product description
This diagram shows the flow of water and hydraulic fluid through the pump system.
WASTEWATER
OUT
Water that goes to
a drain
Water valve
Bleed-down valve
CUTTING WATER IN
Intensifier
CUTTING WATER
OUT
Low-pressure water
from a water softener, a
reverse osmosis
system, a well, or a
public utility
Water that has been
pressurized by the
intensifier for piercing
or cutting
Water-cooled system
COOLING OUT
Cooling loop
COOLING IN
Low-pressure supply
water or water from a
chiller that goes to a
heat exchanger
Low-pressure water
from a heat exchanger
that goes to a drain or
returns to a chiller
Air-cooled system
COOLING OUT
External air cooler
COOLING IN
Hydraulic fluid goes to
an air cooler
Hydraulic fluid returns
from an air cooler