4 – Operation
O
p
eration
Stop the pump
Emergency stop
The EMERGENCY STOP button is intended for urgent disabling of the controls. It is not the preferred method of
turning off the pump.
Push the EMERGENCY STOP button.
The control circuit turns off, which turns off the pump, the primary motor, and the intensifier.
The bleed-down valve opens and discharges water from the system.
The CONTROLS ON button indicator light turns off.
Routine stop during operation
1.
1. Turn OFF the cutting head.
2.
Touch the symbol on the operator interface to turn OFF the pump. The bleed-down valve opens and
discharges water from the system.
Turn off the pump at the end of the day
1.
Turn OFF the cutting head.
2.
Touch the symbol on the operator interface to turn OFF the pump. The bleed-down valve opens and
discharges water from the system.
3.
Turn the cut-pressure control knob anticlockwise until it stops.
4.
Before turning off the pump, turn the cut-pressure control knob anticlockwise to decrease pressure.
5.
Turn OFF the primary breaker disconnect lever on the electrical enclosure door.
6.
Turn OFF the water to the pump.
7.
Clean all water and hydraulic fluid off of the top and bottom decks.
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...