86
HyPrecision 50S/60S/75S
Operator Manual
808690
5 – Preventive maintenance
Preventi
ve maintenance
6.
Use a strap wrench or adjustable pliers to remove the suction strainers inside the tank.
7.
Clean the inside of the tank with a lint-free towel and isopropyl alcohol. Make sure that no debris is left on the
bottom.
8.
Install new suction strainers.
Hand tighten the suction strainer, and then turn it 90 degrees more.
9.
Reconnect the hydraulic hoses.
Refer to the
section, which begins on page 181.
10.
Close the drain valve.
11.
Install the drain valve plug.
12.
Replace the access cover on the tank. Torque the nut to 27 N∙m (20 lbf∙ft).
13.
Remove the used filler-breather cap.
14.
Fill the tank with hydraulic fluid. Make sure that the hydraulic fluid level is at the top mark on the sight gauge.
15.
Install the new filler-breather cap.
16.
Discard the used parts.
CAUTION
Remove all towels from the tank before it is filled.
Do not use soap, detergent, or solvents.
Do not overfill the hydraulic fluid tank.
2
1
1
Suction strainer (to the gear pump)
2
Suction strainer (to the primary pump)
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...