HyPrecision 50S/60S/75S
Operator Manual
808690
57
4 – Operation
O
p
eration
Pump settings screen
The pump settings screen provides access to the system settings menu, the pump set up (configuration), and to
the pressure adjustment screen.
System settings
allow the user to enable and disable pump options. If the system has a proportional control
valve, the settings for proportional ramping are found here.
Idle Shutdown
When enabled, the pump turns off after a specified time (Idle Time) without the
intensifier stroking.
Idle Cooling
When enabled, the pump goes into cooling mode after a specified time (Idle Time)
without the intensifier stroking.
Idle Time (minutes)
Set the number of minutes for Idle Shutdown and Idle Cooling.
Analog Pressure Input
Enable this when a remote 0 V to 10 V input is used to control the proportional valve.
Boost Fault Monitor
When enabled, fault monitoring alerts the operator to a boost pump fault.
Fan Fault Monitor
When enabled, fault monitoring alerts the operator to a fan motor fault.
This is for air-cooled systems.
Summary of Contents for HyPrecision 50S
Page 1: ...HyPrecision 50S 60S 75S Waterjet Pump Operator Manual 808690 Revision 2 English ...
Page 10: ...10 HyPrecision 50S 60S 75S Operator Manual 808690 Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 42: ...42 HyPrecision 50S 60S 75S Operator Manual 808690 3 Options Options ...
Page 68: ...68 HyPrecision 50S 60S 75S Operator Manual 808690 4 Operation Operation ...
Page 172: ...172 HyPrecision 50S 60S 75S Operator Manual 808690 7 Troubleshooting Troubleshooting ...